Accuracy / Deviations Switching point accuracy < ± 0.4; (turn down 1:1) % of span Repeatability < ± 0.1; (at temperature variations < 10 K; Turn down 1:1) % of span Characteristic deviation < ± 0.25 (BFSL) / < ± 0.5 (LS); (turn down 1:1; BFSL = Best Fit Straight Line (minimum setting); LS = endpoint setting) % of span Hysteresis deviation < ± 0.1; (Turn down 1:1) % of span Long-term stability < ± 0.05; (turn down 1:1; per 6 months) % of span Temperature coefficient zero point < ± 0.2; (-0...80 °C) % of span / 10 K Temperature coefficient range < ± 0.2; (-0...80 °C) % of span / 10 K Notes on accuracy / deviation Switching point accuracy, characteristic curve deviation under DNVGL: < ± 1% Approvals / tests EMC DIN EN 61000-6-2; DIN EN 61000-6-3 Shock resistance DIN EN 60068-2-27 / 50 g (11 ms) Vibration resistance DIN EN 60068-2-6 / 20 g (10...2000 Hz) MTTF 138 years UL approval approval number UL / J012 Printer directive Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request Displays / controls Indication Display unit / 5 x LED, green (mbar, psi, kPa, inH2O, inHg); switching state / 2 x LED, yellow; measured values / alphanumeric display, red / green 4-digit Electrical connection Plug connection 1 x M12; Coding: A; Contacts: 4, gold-plated Electrical data Operating voltage 18...30 DC; (according to SELV/PELV) V Electricity consumption < 35 mA Minimum insulation resistance 100; (500 V DC) MΩ Protection class III Standby delay time 0,3 s Reverse polarity protection Yes Integrated watchdog Yes Environmental conditions Ambient temperature -25...80 °C Storage temperature -40...100 °C Degree of protection IP 65; IP 67 Field of application Special feature Gold-plated contacts Measuring element Ceramic-capacitive pressure sensor cell Application for industrial use Media Liquid and gaseous media Medium temperature -25...80 °C Min. bursting pressure 30000 mbar / 450 psi / 3000 kPa Compressive strength 10000 mbar / 145 psi / 1000 kPa Vacuum tightness -1000 mbar / -0.1 MPa Pressure type Relative pressure; vacuum Interfaces Communication interface IO-Link Transmission type COM2 (38.4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Required master port class A; (if PIN 2 not connected: B) Supported DeviceIDs Operating mode / DeviceID; Factory setting / CMPT = 2 / 467; Status_B High Resolution / CMPT = 3 / 983 Note Further information can be found in the IODD-PDF file under "Downloads" Profiles Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable; Function / Device diagnosis Min. process cycle time 2,3 ms IO-Link pressure resolution 1 mbar IO-Link process data (cyclic) Function / bit length; pressure / 14; binary switching information / 2 IO-Link functions (asynchronous) Application-specific marking SIO mode Yes Measurement / adjustment range Analog start point -1000...600 mbar / -14.5...8.7 psi / -29.5...17.7 inHg / -402...240 inH2O / -100...60 kPa Analog endpoint -600...1000 mbar / -8.7...14.5 psi / -17.7...29.5 inHg / -240...402 inH2O / -60...100 kPa Switching point SP -985...1000 mbar / -14.3...14.5 psi / -29.2...29.5 inHg / -396...402 inH2O / -98.5...100 kPa Reverse switch point rP -995...990 mbar / -14.45...14.4 psi / -29.4...29.3 inHg / -400...398 inH2O / -99.5...99 kPa Min. distance between SP and rP 10 mbar / 0.15 psi / 0.3 inHg / 4 inH2O / 1 kPa In steps of 5 mbar / 0.05 psi / 0.1 inHg / 2 inH2O / 0.5 kPa Mechanical data Housing Cylindrical Dimensions Ø 34 / L = 90,7 mm Materials 1.4404 (stainless steel / 316L); PBT+PC-GF30; PBT-GF20; PC Materials in contact with the medium 1.4404 (stainless steel / 316L); Al2O3 (ceramic); FKM Min. pressure cycles 100 million Tightening moment 25...35; (recommended torque; dependent on lubrication, seal and pressure load) Nm Choke element present no (retrofit available) Outputs Total number of outputs 2 Output signal Switching signal; analog signal; IO-Link; (configurable) Electrical version PNP/NPN Number of digital outputs 2 Output function Normally open contact (NO) / Normally closed contact (NC); (configurable) Max. voltage drop switching output DC 2 V Continuous current rating of switching output DC 250 mA Switching frequency DC < 500 Hz Number of analogue outputs 1 Analog output current 4...20; (scalable 1:5) mA Max. load 500 Ω Analog output voltage 0...10; (scalable 1:5) V Minimum load resistance 2000 Ω Short-circuit protection type timed Short-circuit protection Yes Overload resistant Yes Product features Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Measuring range -1...1 bar / -1000...1000 mbar / -14.5...14.5 psi / -29.5...29.5 inHg / -401...401 inH2O / -100...100 kPa Process connection Threaded connection G 1/4 internal thread (DIN EN ISO 1179-2) Response times Response time < 1,5 ms Adjustable delay time dS, dr 0...50 s Process value damping dAP 0...4 s Attenuation analog output dAA 0...4 s Max. rise time analog output 3 ms Software / Programming Parameterization options Hysteresis / window; normally open contact (NO) / normally closed contact (NC); switching / reset delay; damping; display unit; current / voltage output
Elektronischer Drucksensor, -1...1 bar, -1000...1000 mbar, -14,5...14,5 psi, -29,5...29,5 inhg, -401...401 inh2o, -100...100 kpa, G 1/4 Innengewinde, Schaltsignal, Analogsignal, IO-Link, 4...20, (skalierbar 1:5) mA, 0...10, (skalierbar 1:5) V, Steckverbindung, -25...80 °C, IP 65, IP 67, Relativdruck, Vakuum