Accuracy / Deviations
Switching point accuracy< ± 0.4; (turn down 1:1) % of span
Repeatability< ± 0.1; (at temperature variations < 10 K; Turn down 1:1) % of span
Characteristic deviation< ± 0.25 (BFSL) / < ± 0.5 (LS); (turn down 1:1; BFSL = Best Fit Straight Line (minimum setting); LS = endpoint setting) % of span
Hysteresis deviation< ± 0.1; (Turn down 1:1) % of span
Long-term stability< ± 0.05; (turn down 1:1; per 6 months) % of span
Temperature coefficient zero point< ± 0.2; (-0...80 °C) % of span / 10 K
Temperature coefficient range< ± 0.2; (-0...80 °C) % of span / 10 K
Notes on accuracy / deviationSwitching point accuracy, characteristic curve deviation under DNVGL: < ± 1%
Approvals / tests
EMCDIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-27 / 50 g (11 ms)
Vibration resistanceDIN EN 60068-2-6 / 20 g (10...2000 Hz)
MTTF166 years
UL approvalUL approval number UL / J020; File number UL / E174189
Printer directiveGood engineering practice; suitable for fluids of group 2; fluids of group 1 on request
Displays / controls
Indicationdisplay unit / 3 x LED, green (bar, psi, MPa); switching state / 2 x LED, yellow; measured values / alphanumeric display, red / green 4-digit
Electrical connection
Plug connection1 x M12; Coding: A; Contacts: 4, gold-plated
Electrical data
Operating voltage18...30 DC; (according to SELV/PELV) V
Electricity consumption< 35 mA
Minimum insulation resistance100; (500 V DC) MΩ
Protection classIII
Standby delay time0,3 s
Reverse polarity protectionYes
Integrated watchdogYes
Environmental conditions
Ambient temperature-25...80 °C
Storage temperature-40...100 °C
Degree of protectionIP 65; IP 67
Field of application
Special featureGold-plated contacts
Measuring elementCeramic-capacitive pressure sensor cell
Applicationfor industrial use
MediaLiquid and gaseous media
Conditionally suitable forUse in gaseous media at pressures > 25 bar only on request
Medium temperature-25...80 °C
Min. bursting pressure750 bar / 10900 psi / 75 MPa
Compressive strength350 bar / 5100 psi / 35 MPa
Vacuum tightness-1000 mbar / -0.1 MPa
Pressure typeGauge pressure
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38.4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 3.1 / Measuring Sensor; Common - I&D / Identification and Diagnosis
Required master port classA; (if PIN 2 not connected: B)
Min. process cycle time3 ms
IO-Link pressure resolution0.05 bar
IO-Link process data (cyclic)Function / bit length; Pressure / 16; Device status / 4; Binary switching information / 2
IO-Link functions (asynchronous)Application-specific marking
Supported DeviceIDsOperation mode / DeviceID; default / 1200
NoteFurther information can be found in the IODD-PDF file under "Downloads"
SIO modeYes
Measurement / adjustment range
Switching point SP1.3...160 bar / 19...2321 psi / 0.13...16 MPa
Reverse switch point rP0.5...159.2 bar / 7...2309 psi / 0.05...15.92 MPa
Analog start point0...128 bar / 0...1856 psi / 0...12.8 MPa
Analog endpoint32...160 bar / 464...2321 psi / 3.2...16 MPa
Min. distance between SP and rP0.8 bar / 12 psi / 0.08 MPa
In steps of0.1 bar / 1 psi / 0.01 MPa
Mechanical data
HousingCylindrical
DimensionsØ 34 / L = 90,7 mm
Materials1.4404 (stainless steel / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials in contact with the medium1.4404 (stainless steel / 316L); Al2O3 (ceramic); FKM
Min. pressure cycles100 million
Tightening moment25...35; (recommended torque; dependent on lubrication, seal and pressure load) Nm
Choke element presentno (retrofit available)
Outputs
Total number of outputs2
Output signalSwitching signal; analog signal; IO-Link; (configurable)
Electrical versionPNP/NPN
Number of digital outputs2
Output functionNormally open contact (NO) / Normally closed contact (NC); (configurable)
Max. voltage drop switching output DC2 V
Continuous current rating of switching output DC250 mA
Switching frequency DC< 500 Hz
Number of analogue outputs1
Analog output current4...20; (scalable 1:5) mA
Max. load500 Ω
Analog output voltage0...10; (scalable 1:5) V
Minimum load resistance2000 Ω
Short-circuit protection typetimed
Short-circuit protectionYes
Overload resistantYes
Product features
Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1
Measuring range0...160 bar / 0...2320 psi / 0...16 MPa
Process connectionThreaded connection G 1/4 internal thread (DIN EN ISO 1179-2)
Response times
Response time< 1,5 ms
Adjustable delay time dS, dr0...50 s
Process value damping dAP0...4 s
Attenuation analog output dAA0...4 s
Max. rise time analog output3 ms
Software / Programming
Parameterization optionsHysteresis / window; normally open contact (NO) / normally closed contact (NC); switching / reset delay; damping; display unit; current / voltage output
Elektronischer Drucksensor, 0...160 bar, 0...2320 psi, 0...16 MPa, G 1/4 Innengewinde, Schaltsignal, Analogsignal, IO-Link, 4...20, (skalierbar 1:5) mA, 0...10, (skalierbar 1:5) V, Steckverbindung, -25...80 °C, IP 65, IP 67, Relativdruck
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/832412
qrcode für ifm Electronic PN2012 pressure sensor 0...160 bar G 1/4 internal