| Accuracy / Deviations |
| Switching point accuracy | < ± 2.5; (setting accuracy) % of end value |
| Repeatability | < ± 0.5; (with temperature variations < 10 K) % of end value |
| Characteristic deviation | < ± 1.5 (BFSL) / < ± 2.5 (LS); (BFSL = Best Fit Straight Line (minimum setting); LS = endpoint setting) % of full scale |
| Temperature influence per 10 K | < ± 0,5 |
| Approvals / tests |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN IEC 68-2-27 / 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6 / 20 g (10...2000 Hz) |
| MTTF | 513 years |
| Printer directive | Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request |
| Displays / controls |
| Indication | Switching state / 2 x LED, yellow |
| Scale present | |
| Electrical connection |
| Plug connection | 1 x M12; coding: A; contacts: 4 |
| Electrical data |
| Operating voltage | 9,6...32 DC V |
| Electricity consumption | < 25 mA |
| Minimum insulation resistance | 100; (500 V DC) MΩ |
| Protection class | III |
| Reverse polarity protection | |
| Environmental conditions |
| Ambient temperature | -25...80 °C |
| Storage temperature | -40...100 °C |
| Degree of protection | IP 67 |
| Field of application |
| Application | for industrial use |
| Media | Liquid and gaseous media |
| Medium temperature | -25...80 °C |
| Min. bursting pressure | 1000 bar / 14500 psi / 100 MPa |
| Compressive strength | 200 bar / 2900 psi / 20 MPa |
| Pressure type | Gauge pressure |
| Measurement / adjustment range |
| Switching point SP | 3...100 bar / 45...1450 psi |
| Hysteresis | 2 bar / 29 psi |
| Mechanical data |
| Housing | Cylindrical |
| Dimensions | Ø 27 / L = 71,6 mm |
| Materials | PBT; PC; FKM; 1.4404 (stainless steel / 316L) |
| Materials in contact with the medium | 1.4404 (stainless steel / 316L); FKM |
| Min. pressure cycles | 50 million |
| Tightening moment | 25 Nm |
| Choke element present | no (retrofit available) |
| Outputs |
| Total number of outputs | 2 |
| Output signal | Switching signal |
| Electrical version | PNP |
| Number of digital outputs | 2 |
| Output function | Normally open contact |
| Max. voltage drop switching output DC | 2 V |
| Continuous current rating of switching output DC | 500 mA |
| Switching frequency DC | 100 Hz |
| Short-circuit protection type | timed |
| Short-circuit protection | |
| Overload resistant | |
| Product features |
| Number of inputs and outputs | Number of digital outputs: 2 |
| Measuring range | 0...100 bar / 0...1450 psi |
| Process connection | Threaded connection G 1/4 male thread; Internal thread: M5 |
| Software / Programming |
| Switching point adjustment | Adjustment rings |
Electronic pressure switch, 0...100 bar, 0...1450 psi, G 1/4 external thread, switching signal, plug connection, -25...80 °C, IP 67, relative pressure