Further information for ifm Electronic PI1889 pressure sensor -5...100 mbar G 1 external
Accuracy / Deviations
Switching point accuracy
< ± 0.5; (DIN EN IEC 62828-1; turn down 1:1) % of span
Repeatability
< ± 0.2; (with temperature variations < 10 K; turn down 1:1) % of span
Characteristic deviation
< ± 0.5; (DIN IEC EN 62828-1 including zero point and span error, non-linearity, hysteresis; Turn down 1:1) % of span
Linearity deviation
< ± 0.25; (turn down 1:1) % of span
Neutral point stabilisation
IO-Link, analogue output / 0.4; (See operating manual for zero point behaviour); Display, switching output / 0.4 % of range
Hysteresis deviation
< ± 0.2; (Turn down 1:1) % of span
Long-term stability
< ± 0.1; (turn down 1:1; per year) % of span
Total deviation over temperature range
Temperature range / total deviation; -25...15 °C / characteristic deviation ± 0.15 % of span / 10 K; 15...80 °C / characteristic deviation; 80...150 °C / characteristic deviation ± 0.2 % of span / 10 K
Notes on accuracy / deviation
Further information see section Diagrams and curves.
Accuracy
± 2.5+ (0.08 x (ambient temperature - medium temperature)) K
Resolution
0,2 K
Approvals / tests
EMC
DIN EN 61326-1
Shock resistance
DIN EN 60068-2-27 / 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 / 20 g (10...2000 Hz)
MTTF
214 years
UL approval
Approval number UL / J049; File number UL / E174189
Displays / controls
Indication
Display unit / LED, green; Switching state / LED, yellow; Function indicator / alphanumeric display, 4-digit; Measured values / alphanumeric display, 4-digit
Display unit
mbar; kPa; inH2O
Electrical connection
Plug connection
1 x M12; Coding: A; Contacts: 4, gold-plated
Electrical data
Minimum insulation resistance
100; (500 V DC) MΩ
Protection class
III
Operating voltage
20...30 DC V
Electricity consumption
3,5...21,5 mA
Standby delay time
< 1 s
Reverse polarity protection
Integrated watchdog
Environmental conditions
Ambient temperature
-25...80 °C
Storage temperature
-40...100 °C
Degree of protection
IP 67; IP 68; IP 69K
Field of application
Special feature
Gold-plated contacts
Application
Flush-mounted for food and beverage industry
Media
Paste and solid-containing media; Liquid and gaseous media
Medium temperature
-25...150 °C
Min. bursting pressure
30000 mbar / 12044 inH2O / 3000 kPa
Compressive strength
4000 mbar / 1606 inH2O / 400 kPa
Vacuum tightness
-1000 mbar / -0.1 MPa
Pressure type
Relative pressure; vacuum
MAWP for applications according to CRN
4 bar
Backlash-free
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Common - I&D / Identification and Diagnosis; Function / Measurement data, high resolution
Required master port class
A
Min. process cycle time
5,6 ms
IO-Link pressure resolution
0.005 mbar
IO-Link resolution temperature
0,2 K
IO-Link process data (cyclic)
Function / bit length; pressure / 32; temperature / 32; device status / 4; binary switching information / 2
Threaded connection G 1 external thread sealing cone - 27 mm; Note: The device may only be mounted in a process connection for G1 sealing cone!; The G1A sealing cone of the device is only suitable for adapters with metallic mating surface!
Response times
Process value damping dAP
0...99,99 s
Attenuation analog output dAA
0...99,99 s
Step response time analog output
30 ms
Min. response time relay output dAP
3 ms
Response dynamics T05 / T09
< 45 / < 200; (DIN EN 60751 water ; > 0.9 m/s) s
Elektronischer Drucksensor, -0,005...0,1 bar, -5...100 mbar, -2...40,15 inh2o, -0,5...10 kpa, G 1 Außengewinde Dichtkonus, Schaltsignal, Analogsignal, IO-Link, 4...20, invertierbar, (skalierbar) mA, Steckverbindung, -25...150 °C, IP 67, IP 68, IP 69K, Relativdruck, Vakuum