Further information for ifm Electronic PI1804 pressure sensor -1...10 bar G 1 external
Accuracy / Deviations
Switching point accuracy
< ± 0.2; (DIN EN IEC 62828-1; Turn down 1:1) % of span
Repeatability
< ± 0.1; (at temperature variations < 10 K; Turn down 1:1) % of span
Characteristic deviation
< ± 0.2; (DIN IEC EN 62828-1 including zero point and span error, non-linearity, hysteresis; turn down 1:1) % of span
Linearity deviation
< ± 0.15; (turn down 1:1) % of span
Neutral point stabilisation
IO-Link, analogue output / 0.15; (See operating manual for zero point behaviour); Display, switching output / 0.2 % of range
Hysteresis deviation
< ± 0.15; (turn down 1:1) % of span
Long-term stability
< ± 0.1; (turn down 1:1; per year) % of span
Total deviation over temperature range
Temperature range / total deviation; -25...15 °C / characteristic deviation ± 0.05 % of span / 10 K; 15...80 °C / characteristic deviation; 80...150 °C / characteristic deviation ± 0.1 % of span / 10 K
Notes on accuracy / deviation
Further information see section Diagrams and curves.
Accuracy
± 2.5+ (0.08 x (ambient temperature - medium temperature)) K
Resolution
0,2 K
Approvals / tests
EMC
DIN EN 61326-1
Shock resistance
DIN EN 60068-2-27 / 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 / 20 g (10...2000 Hz)
MTTF
214 years
UL approval
Approval number UL / J049; File number UL / E174189
Displays / controls
Indication
Display unit / LED, green; Switching state / LED, yellow; Function indicator / alphanumeric display, 4-digit; Measured values / alphanumeric display, 4-digit
Display unit
bar; psi; MPa
Electrical connection
Plug connection
1 x M12; Coding: A; Contacts: 4, gold-plated
Electrical data
Minimum insulation resistance
100; (500 V DC) MΩ
Protection class
III
Operating voltage
20...30 DC V
Electricity consumption
3,5...21,5 mA
Standby delay time
< 1 s
Reverse polarity protection
Integrated watchdog
Environmental conditions
Ambient temperature
-25...80 °C
Storage temperature
-40...100 °C
Degree of protection
IP 67; IP 68; IP 69K
Field of application
Special feature
Gold-plated contacts
Application
Flush-mounted for food and beverage industry
Media
Paste and solid-containing media; Liquid and gaseous media
Medium temperature
-25...150 °C
Min. bursting pressure
150 bar / 2175 psi / 15 MPa
Compressive strength
50 bar / 725 psi / 5 MPa
Vacuum tightness
-1000 mbar / -0.1 MPa
Pressure type
Relative pressure; vacuum
MAWP for applications according to CRN
50 bar
Backlash-free
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Common - I&D / Identification and Diagnosis; Function / Measurement data, high resolution
Required master port class
A
Min. process cycle time
5,6 ms
IO-Link pressure resolution
0.0005 bar
IO-Link resolution temperature
0,2 K
IO-Link process data (cyclic)
Function / bit length; pressure / 32; temperature / 32; device status / 4; binary switching information / 2
Normally open contact (NO) / Normally closed contact (NC); (configurable)
Number of analogue outputs
1
Analog output current
4...20, reversible; (scalable) mA
Short-circuit protection type
timed
Max. load
300 Ω
Max. voltage drop switching output DC
2 V
Continuous current rating of switching output DC
100 mA
Switching frequency DC
125 Hz
Short-circuit protection
Overload resistant
Product features
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Measuring range
-1...10 bar / -14.6...145 psi / -0.1...1 MPa
Process connection
Threaded connection G 1 external thread sealing cone - 27 mm; Note: The device may only be mounted in a process connection for G1 sealing cone!; The G1A sealing cone of the device is only suitable for adapters with metallic mating surface!
Response times
Process value damping dAP
0...99,99 s
Attenuation analog output dAA
0...99,99 s
Step response time analog output
30 ms
Min. response time relay output dAP
3 ms
Response dynamics T05 / T09
< 45 / < 200; (DIN EN 60751 water ; > 0.9 m/s) s
Elektronischer Drucksensor, -1...10 bar, -14,6...145 psi, -0,1...1 MPa, G 1 Außengewinde Dichtkonus, Schaltsignal, Analogsignal, IO-Link, 4...20, invertierbar, (skalierbar) mA, Steckverbindung, -25...150 °C, IP 67, IP 68, IP 69K, Relativdruck, Vakuum