Further information for ifm Electronic PI1715 pressure sensor -1...6 bar G 1 external
Accuracy / Deviations
Switching point accuracy
< ± 0.2; (DIN EN IEC 62828-1; Turn down 1:1) % of span
Repeatability
< ± 0.1; (at temperature variations < 10 K; Turn down 1:1) % of span
Characteristic deviation
< ± 0.2; (DIN IEC EN 62828-1 including zero point and span error, non-linearity, hysteresis; turn down 1:1) % of span
Linearity deviation
< ± 0.15; (turn down 1:1) % of span
Neutral point stabilisation
IO-Link, analogue output / 0.15; (See operating manual for zero point behaviour); Display, switching output / 0.2 % of range
Hysteresis deviation
< ± 0.15; (turn down 1:1) % of span
Long-term stability
< ± 0.1; (turn down 1:1; per year) % of span
Total deviation over temperature range
Temperature range / total deviation; -25...15 °C / characteristic deviation ± 0.05 % of span / 10 K; 15...80 °C / characteristic deviation; 80...150 °C / characteristic deviation ± 0.1 % of span / 10 K
Notes on accuracy / deviation
Further information see section Diagrams and curves.
Accuracy
± 2.5+ (0.08 x (ambient temperature - medium temperature)) K
Resolution
0,2 K
Approvals / tests
EMC
DIN EN 61326-1
Shock resistance
DIN EN 60068-2-27 / 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 / 20 g (10...2000 Hz)
MTTF
214 years
UL approval
Approval number UL / J048; File number UL / E174189
Displays / controls
Indication
Display unit / LED, green; Switching state / LED, yellow; Function indicator / alphanumeric display, 4-digit; Measured values / alphanumeric display, 4-digit
Display unit
bar; psi; kPa
Electrical connection
Plug connection
1 x M12; Coding: A; Contacts: 4, gold-plated
Electrical data
Minimum insulation resistance
100; (500 V DC) MΩ
Protection class
III
Operating voltage
20...30 DC V
Electricity consumption
3,5...21,5 mA
Standby delay time
< 1 s
Reverse polarity protection
Integrated watchdog
Environmental conditions
Ambient temperature
-25...80 °C
Storage temperature
-40...100 °C
Degree of protection
IP 67; IP 68; IP 69K
Field of application
Special feature
Gold-plated contacts
Application
Flush-mounted for food and beverage industry
Media
Paste and solid-containing media; Liquid and gaseous media
Medium temperature
-25...150 °C
Min. bursting pressure
100 bar / 1450 psi / 10000 MPa
Compressive strength
30 bar / 435 psi / 3000 kPa
Vacuum tightness
-1000 mbar / -0.1 MPa
Pressure type
Relative pressure; vacuum
MAWP for applications according to CRN
6 bar
Backlash-free
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Common - I&D / Identification and Diagnosis; Function / Measurement data, high resolution
Required master port class
A
Min. process cycle time
5,6 ms
IO-Link pressure resolution
0.0002 bar
IO-Link resolution temperature
0,2 K
IO-Link process data (cyclic)
Function / bit length; pressure / 32; temperature / 32; device status / 4; binary switching information / 2