| Accuracy / Deviations |
| Switching point accuracy | < ± 0.2; (Turn down 1:1) % of span |
| Repeatability | < ± 0.1; (at temperature variations < 10 K; Turn down 1:1) % of span |
| Characteristic deviation | < ± 0.2; (Turn down 1:1, linearity, including hysteresis and repeatability, setpoint adjustment according to DIN EN IEC 62828-1) % of span |
| Linearity deviation | < ± 0.15; (turn down 1:1) % of span |
| Hysteresis deviation | < ± 0.15; (turn down 1:1) % of span |
| Long-term stability | < ± 0.1; (turn down 1:1; per year) % of span |
| Temperature coefficient zero point | < ± 0.05; (0...70 °C) % of range / 10 K |
| Temperature coefficient range | < ± 0.15; (0...70 °C) % of span / 10 K |
| Approvals / tests |
| ATEX equipment marking | II 3D Ex tc IIIC T90°C Dc X; II 3G Ex nA IIC T4 Gc X |
| EMC | EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 Radiated HF / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-5 Surge / 0.5/1 kV; EN 61000-4-6 Conducted HF / 10 V |
| Shock resistance | DIN IEC 68-2-27 / 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6 / 20 g (10...2000 Hz) |
| MTTF | 163 years |
| Displays / controls |
| Indication | Display unit / 4 x LED, green; Switching state / LED, yellow; Function indicator / alphanumeric display, 4-digit; Measured values / alphanumeric display, 4-digit |
| Display unit | bar; psi; MPa; % of span |
| Electrical connection |
| Plug connection | 1 x M12; Coding: A; Contacts: 4, gold-plated |
| Electrical data |
| Operating voltage | 18...32 DC V |
| Electricity consumption | < 50 mA |
| Protection class | III |
| Standby delay time | 0,5 s |
| Reverse polarity protection | |
| Integrated watchdog | |
| Environmental conditions |
| Ambient temperature | -20...60 °C |
| Storage temperature | -40...100 °C |
| Degree of protection | IP 65 |
| Field of application |
| Special feature | Gold-plated contacts |
| Application | for industrial use; for applications in explosive atmospheres |
| Mounting | Rotatable housing 350° |
| Media | Paste and solid-containing media; Liquid and gaseous media |
| Medium temperature | -20...60; (when used outside Ex area: ambient temperature: -25...85 °C; medium temperature: -25...125 °C / 145 °C < 1h) °C |
| Min. bursting pressure | 350 bar / 5070 psi / 35 MPa |
| Compressive strength | 100 bar / 1450 psi / 10 MPa |
| Pressure type | Relative pressure; vacuum |
| Measurement / adjustment range |
| Switching point SP | -0.96...25 bar / -13.8...362.7 psi / -0.096...2.5 MPa |
| Reverse switch point rP | -1...24.96 bar / -14.4...362.1 psi / -0.1...2.496 MPa |
| Analog start point | -1...18.74 bar / -14.4...271.8 psi / -0.1...1.874 MPa |
| Analog endpoint | 5.24...25 bar / 76.2...362.7 psi / 0.524...2.5 MPa |
| In steps of | 0.02 bar / 0.3 psi / 0.002 MPa |
| Mechanical data |
| Housing | Cylindrical |
| Dimensions | Ø 36 / L = 132 mm |
| Materials | 1.4404 (Stainless steel / 316L); PC; PBT; PEI; FKM; PTFE |
| Materials in contact with the medium | Ceramic (99.9 % Al2O3); 1.4435 (stainless steel / 316L); 1.4404 (stainless steel / 316L) surface finish: Ra < 0.4 µm / Rz = 4 µm; PTFE; EPDM |
| Min. pressure cycles | 100 million |
| Outputs |
| Total number of outputs | 2 |
| Output signal | Switching signal; analog signal; (configurable) |
| Electrical version | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | Normally open contact (NO) / Normally closed contact (NC); (configurable) |
| Max. voltage drop switching output DC | 2 V |
| Continuous current rating of switching output DC | 250 mA |
| Switching frequency DC | 6 Hz |
| Number of analogue outputs | 1 |
| Analog output current | 4...20, reversible; (scalable 1:4) mA |
| Max. load | (Ub - 10 V) / 20 mA Ω |
| Analog output voltage | 0...10, invertible; (scalable 1:4) V |
| Minimum load resistance | 2000 Ω |
| Short-circuit protection type | timed |
| Short-circuit protection | |
| Overload resistant | |
| Product features |
| Number of inputs and outputs | Number of digital outputs: 1; Number of analog outputs: 1 |
| Measuring range | -1...25 bar / -14.4...362.7 psi / -0.1...2.5 MPa |
| Process connection | Thread connection G 1 external thread sealing cone - 27 mm |
| Response times |
| Response time | < 100 ms |
| Process value damping dAP | 0,1...100 s |
| Attenuation analog output dAA | 0,1...100 s |
| Step response time analog output | 25 ms |
| Software / Programming |
| Parameterization options | Hysteresis / window; Normally open contact (NO) / Normally closed contact (NC); Switching logic; Current/voltage output; Damping; Display value adjustment; Rotatable / switchable display; Display unit; Zero point; Range |
Combi-Drucksensor, -1...25 bar, -14,4...362,7 psi, -0,1...2,5 MPa, G 1 Außengewinde Dichtkonus, Schaltsignal, Analogsignal, 4...20, invertierbar, (skalierbar 1:4) mA, 0...10, invertierbar, (skalierbar 1:4) V, Steckverbindung, -20...60, (bei Anwendung außerhalb des Ex-Bereichs:, Umgebungstemperatur: -25...85 °C, Mediumtemperatur: -25...125 °C / 145 °C < 1h) °C, IP 65, Relativdruck, Vakuum