Further information for Ifm Electronic PG2457 - Electronic pressure sensor
with analogue display Connector
Accuracy / Deviations
Switching point accuracy
< ± 0.5; (Turn down 1:1) % of span
Repeatability
< ± 0.1; (at temperature variations < 10 K; Turn down 1:1) % of span
Characteristic deviation
< ± 0.25 (BFSL) / < ± 0.5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line (minimum setting)) % of span
Hysteresis deviation
< ± 0.25; (turn down 1:1) % of span
Long-term stability
< ± 0.1; (turn down 1:1; per 6 months) % of span
Temperature coefficient zero point
< ± 0.2; (0...70 °C) % of span / 10 K
Temperature coefficient range
< ± 0.2; (0...70 °C) % of span / 10 K
Approvals / tests
EMC
EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 Radiated HF / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-5 Surge / 0.5/1 kV; EN 61000-4-6 Conducted HF / 10 V
Shock resistance
DIN EN 60068-2-27 / 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 / 10 g (10...2000 Hz)
MTTF
103 years
Printer directive
Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request
Displays / controls
Indication
Display unit / 2 x LED, green; switching state / LED, yellow; switching points / LED ring, red; function indicator / alphanumeric display, red 4-digit; measured values / analogue display, 0...350° rotatable, pointer not visible in de-energised state; measured values / alphanumeric display, red 4-digit