Further information for ifm Electronic PE2099 pressure sensor -1...1 bar G 1/4 internal IO-Link
Accuracy / Deviations
Switching point accuracy
< ± 0.4; (turn down 1:1) % of span
Repeatability
< ± 0.1; (at temperature variations < 10 K; Turn down 1:1) % of span
Characteristic deviation
< ± 0.25 (BFSL) / < ± 0.5 (LS); (turn down 1:1; BFSL = Best Fit Straight Line (minimum setting); LS = endpoint setting) % of span
Hysteresis deviation
< ± 0.1; (Turn down 1:1) % of span
Long-term stability
< ± 0.05; (turn down 1:1; per 6 months) % of span
Temperature coefficient zero point
0.2; (-25...80 °C) % of span / 10 K
Temperature coefficient range
0.2; (-25...80 °C) % of span / 10 K
Notes on accuracy / deviation
Switching point accuracy, characteristic curve deviation under DNVGL: < ± 1%
Approvals / tests
EMC
DIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 / 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 / 20 g (10...2000 Hz)
MTTF
171 years
UL approval
approval number UL / J012
Printer directive
Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request
Displays / controls
Indication
Display unit / 5 x LED, green (mbar, psi, kPa, inH2O, inHg); switching state / 2 x LED, yellow; measured values / alphanumeric display, red / green 4-digit
Electrical connection
Plug connection
1 x M12; Coding: A; Contacts: 4, gold-plated
Electrical data
Operating voltage
18...30 DC; (according to SELV/PELV) V
Electricity consumption
< 35 mA
Minimum insulation resistance
100; (500 V DC) MΩ
Protection class
III
Standby delay time
0,3 s
Reverse polarity protection
Integrated watchdog
Environmental conditions
Ambient temperature
-25...80 °C
Storage temperature
-40...100 °C
Degree of protection
IP 65; IP 67
Field of application
Special feature
Gold-plated contacts
Measuring element
Ceramic-capacitive pressure sensor cell
Application
for industrial use
Media
Liquid and gaseous media
Medium temperature
-25...80 °C
Min. bursting pressure
30000 mbar / 435 psi / 3000 kPa
Compressive strength
10000 mbar / 145 psi / 1000 kPa
Vacuum tightness
-1000 mbar / -0.1 MPa
Pressure type
Gauge pressure
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable; Function / Device diagnosis