Ifm Electronic PE2099, EAN: 4021179308496

ifm Electronic PE2099 pressure sensor -1...1 bar G 1/4 internal IO-Link

ifm Electronic PE2099 pressure sensor -1...1 bar G 1/4 internal IO-Link

Lieske Part No. 695202
Mfg Part No PE2099
EAN-Code 4021179308496
Manufacturer Ifm Electronic
Here only 505,07 EUR
601,03 EUR incl. VAT

Further information for ifm Electronic PE2099 pressure sensor -1...1 bar G 1/4 internal IO-Link

Accuracy / Deviations
Switching point accuracy< ± 0.4; (turn down 1:1) % of span
Repeatability< ± 0.1; (at temperature variations < 10 K; Turn down 1:1) % of span
Characteristic deviation< ± 0.25 (BFSL) / < ± 0.5 (LS); (turn down 1:1; BFSL = Best Fit Straight Line (minimum setting); LS = endpoint setting) % of span
Hysteresis deviation< ± 0.1; (Turn down 1:1) % of span
Long-term stability< ± 0.05; (turn down 1:1; per 6 months) % of span
Temperature coefficient zero point0.2; (-25...80 °C) % of span / 10 K
Temperature coefficient range0.2; (-25...80 °C) % of span / 10 K
Notes on accuracy / deviationSwitching point accuracy, characteristic curve deviation under DNVGL: < ± 1%
Approvals / tests
EMCDIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-27 / 50 g (11 ms)
Vibration resistanceDIN EN 60068-2-6 / 20 g (10...2000 Hz)
MTTF171 years
UL approvalapproval number UL / J012
Printer directiveGood engineering practice; suitable for fluids of group 2; fluids of group 1 on request
Displays / controls
IndicationDisplay unit / 5 x LED, green (mbar, psi, kPa, inH2O, inHg); switching state / 2 x LED, yellow; measured values / alphanumeric display, red / green 4-digit
Electrical connection
Plug connection1 x M12; Coding: A; Contacts: 4, gold-plated
Electrical data
Operating voltage18...30 DC; (according to SELV/PELV) V
Electricity consumption< 35 mA
Minimum insulation resistance100; (500 V DC) MΩ
Protection classIII
Standby delay time0,3 s
Reverse polarity protectionYes
Integrated watchdogYes
Environmental conditions
Ambient temperature-25...80 °C
Storage temperature-40...100 °C
Degree of protectionIP 65; IP 67
Field of application
Special featureGold-plated contacts
Measuring elementCeramic-capacitive pressure sensor cell
Applicationfor industrial use
MediaLiquid and gaseous media
Medium temperature-25...80 °C
Min. bursting pressure30000 mbar / 435 psi / 3000 kPa
Compressive strength10000 mbar / 145 psi / 1000 kPa
Vacuum tightness-1000 mbar / -0.1 MPa
Pressure typeGauge pressure
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38.4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable; Function / Device diagnosis
Required master port classA
Analog process data1
Process data binary2
Min. process cycle time2,3 ms
Supported DeviceIDsOperation mode / DeviceID; default / 467
SIO modeYes
Measurement / adjustment range
Switching point SP-985...1000 mbar / -14.3...14.5 psi / -98.5...100 kPa
Reverse switch point rP-995...990 mbar / -14.45...14.4 psi / -99.5...99 kPa
Analog start point-1000...600 mbar / -14.5...8.7 psi / -100...60 kPa
Analog endpoint-600...1000 mbar / -8.7...14.5 psi / -60...100 kPa
In steps of5 mbar / 0.05 psi / 0.5 kPa
Mechanical data
HousingCylindrical
DimensionsØ 34 / L = 90,7 mm
Materials1.4404 (stainless steel / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials in contact with the medium1.4404 (stainless steel / 316L); Al2O3 (ceramic); EPDM
Min. pressure cycles100 million
Tightening moment25...35; (recommended torque; dependent on lubrication, seal and pressure load) Nm
Choke element presentno (retrofit available)
Outputs
Total number of outputs2
Output signalSwitching signal; analog signal; IO-Link; (configurable)
Electrical versionPNP/NPN
Number of digital outputs2
Output functionNormally open contact (NO) / Normally closed contact (NC); (configurable)
Max. voltage drop switching output DC2 V
Continuous current rating of switching output DC250 mA
Switching frequency DC< 500 Hz
Number of analogue outputs1
Analog output current4...20; (scalable 1:5) mA
Max. load500 Ω
Analog output voltage0...10; (scalable 1:5) V
Minimum load resistance2000 Ω
Short-circuit protection typetimed
Short-circuit protectionYes
Overload resistantYes
Product features
Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1
Measuring range-1...1 bar / -1000...1000 mbar / -14.5...14.5 psi / -100...100 kPa
Process connectionthreaded connection G 1/4 internal thread
Response times
Response time< 1,5 ms
Adjustable delay time dS, dr0...50 s
Process value damping dAP0...4 s
Attenuation analog output dAA0...4 s
Max. rise time analog output3 ms
Software / Programming
Parameterization optionsHysteresis / window; normally open contact (NO) / normally closed contact (NC); switching / reset delay; damping; display unit; current / voltage output
Elektronischer Drucksensor, -1...1 bar, -1000...1000 mbar, -14,5...14,5 psi, -100...100 kpa, G 1/4 Innengewinde, Schaltsignal, Analogsignal, IO-Link, 4...20, (skalierbar 1:5) mA, 0...10, (skalierbar 1:5) V, Steckverbindung, -25...80 °C, IP 65, IP 67, Relativdruck
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/695202
qrcode für ifm Electronic PE2099 pressure sensor -1...1 bar G 1/4 internal IO-Link