Further information for ifm Electronic PC9050 pressure sensor 0...400 bar G 1/4
Accuracy / Deviations
Repeatability
< ± 0.1; (with temperature variations < 10 K) % of span
Characteristic deviation
< ± 1.0; (including screw-in drift, zero point and span error) % of span
Linearity deviation
< ± 0.25 (BFSL) / < ± 0.5 (LS) % of span
Hysteresis deviation
< ± 0.2 % of span
Long-term stability
< ± 0.1; (per 6 months) % of span
Temperature influence per 10 K
< ± 0,5
Approvals / tests
EMC
Electromagnetic compatibility / according to automotive directive 1995/54/EC; ISO 11452-2 / 100 V/m; ISO 11452-4 / 100 mA / severity level 4; DIN EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; DIN EN 61000-6-2; electromagnetic emission; CISPR 25; DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 / 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 / 20 g (10...2000 Hz)
MTTF
3896 years
UL approval
UL certification number / J04X
Electrical connection
Plug connection
1 x M12; coding: A; contacts: 4
Electrical data
Operating voltage
5 DC; (ratiometric) V
Electricity consumption
< 6 mA
Minimum insulation resistance
100; (80 V DC) MΩ
Protection class
III
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...90 °C
Storage temperature
-40...100 °C
Degree of protection
IP 67; IP 69K
Field of application
Application
For mobile use
Media
Liquid and gaseous media
Medium temperature
-25...90; (on request: -40...100 °C) °C
Min. bursting pressure
1600 bar / 160 MPa
Compressive strength
600 bar / 60 MPa
Pressure type
Gauge pressure
Mechanical data
Housing
Cylindrical
Dimensions
Ø 22 / L = 65,1 mm
Materials
1.4404 (stainless steel / 316L); PA
Materials in contact with the medium
1.4404 (stainless steel / 316L); FKM
Min. pressure cycles
50 million
Choke element present
Outputs
Total number of outputs
1
Output signal
Analog signal
Number of analogue outputs
1
Analog output voltage
0,5...4,5 V
Minimum load resistance
5000 Ω
Product features
Number of inputs and outputs
Number of analog outputs: 1
Measuring range
0...400 bar / 0...40000 kPa
Process connection
Threaded connection G 1/4 male thread
Remarks
Remarks
BFSL = Best Fit Straight Line (minimum setting); LS = limit point setting
Response times
Step response time analog output
8 ms
Elektronischer Drucksensor, 0...400 bar, 0...40000 kpa, G 1/4 Außengewinde, Analogsignal, 0,5...4,5 V, Steckverbindung, -25...90, (auf Anfrage: -40...100 °C) °C, IP 67, IP 69K, Relativdruck