Accuracy / Deviations Repeatability < ± 0.05; (with temperature variations < 10 K) % of span Characteristic deviation < ± 0.8 (-25…65 °C); < ± 1.5 (-40...90 °C); (including screw-in drift, zero point and span error, non-linearity, hysteresis) % of range Linearity deviation < ± 0.1 (BFSL) / < ± 0.2 (LS) % of span Hysteresis deviation < ± 0.2 % of span Long-term stability < ± 0.1; (per 6 months) % of span Temperature coefficient zero point and span < 0.25 (-40...90 °C) % of span / 10 K Approvals / tests EMC DIN EN 61000-6-2; DIN EN 61000-6-3 Shock resistance DIN EN 60068-2-27 / 500 g (1 ms) Vibration resistance DIN EN 60068-2-6 / 20 g (10...2000 Hz) MTTF 787 years Printer directive Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request Electrical connection Plug connection 1 x M12; coding: A; contacts: 2 Electrical data Operating voltage 8,5...36 DC V Minimum insulation resistance 100; (500 V DC) MΩ Protection class III Standby delay time 0,1 s Reverse polarity protection Yes Environmental conditions Ambient temperature -40...90 °C Storage temperature -40...100 °C Degree of protection IP 67; IP 69K Field of application Measuring element metallic thin-film cell Application for industrial use Media Liquid and gaseous media Medium temperature -40...90 °C Min. bursting pressure 300 bar / 4350 psi / 30 MPa Compressive strength 25 bar / 360 psi / 2.5 MPa Note on pressure resistance Static Vacuum tightness -1000 mbar / -0.1 MPa Pressure type Gauge pressure Mechanical data Housing Cylindrical Dimensions Ø 19 / L = 66 mm Materials 1.4542 (stainless steel / 17-4 PH / 630); 1.4404 (stainless steel / 316L); PEI Materials in contact with the medium 1.4542 (Stainless steel / 17-4 PH / 630) Min. pressure cycles 60 million; (at 1.2 times rated pressure) Tightening moment 25...35; (recommended torque; dependent on lubrication, seal and pressure load) Nm Sealing of process connection FKM (DIN EN ISO 1179-2) Choke element present no (retrofit available) Outputs Total number of outputs 1 Output signal Analog signal Number of analogue outputs 1 Analog output current 4...20 mA Max. load 755; (Ub = 24 V; (Ub - 8,5 V) / 20,5 mA) Ω Short-circuit-proof Yes Overload resistant Yes Product features Number of inputs and outputs Number of analog outputs: 1 Measuring range 0...10 bar / 0...145 psi / 0...1000 kPa / 0...1 MPa Process connection Threaded connection G 1/4 male thread Remarks Remarks BFSL = Best Fit Straight Line (minimum setting); LS = limit point setting Response times Step response time analog output 1 ms
Elektronischer Drucksensor, 0...10 bar, 0...145 psi, 0...1000 kpa, 0...1 MPa, G 1/4 Außengewinde, Analogsignal, 4...20 mA, Steckverbindung, -25...65 °C, IP 67, IP 69K, Relativdruck