Further information for ifm Electronic OMH550 optical distance sensor red light IP65
Accuracy / Deviations
Repeatability
0,03 mm
Resolution
0,01 mm
Notes on accuracy / deviation
The specified values are reached after a warm-up time of 20 minutes.
Temperature compensation
Approvals / tests
EMC
EN 61000-4-2 ESD / 4 kV CD / plastic; 8 kV AD / metal; EN 61000-4-3 radiated RF / 10 V/m; EN 61000-4-6 conducted RF / 10 V; EN 61000-4-4 burst / 2 kV; EN 55011 / Class B
Vibration resistance
EN 60068-2-6 Fc / (10-55) Hz 1 mm amplitude, vibration duration 5 min., 30 min. per axis at resonance or 55 Hz
Shock resistance
EN 60068-2-27 Ea / 30 g 11 ms half-sine; 3 shocks in each direction of the 3 coordinate axes
Laser safety warning
Caution: / Laser light; Laser class: / 1; EN/IEC 60825-1 2007; EN/IEC 60825-1 2014; Complies with 21 CFR 1040.10 except for conformance with IEC 60825-1 Ed. 3, as described in Laser Notice No. 56, dated May 8, 2019.
MTTF
572 years
UL approval
Power supply / Class 2
Detection range
Max. light spot diameter
0,5 mm
Light spot dimensions apply to
at maximum range
Adjustable range/sensing range
Displays / controls
Indication
Switching state / 2 LED, yellow; Supply voltage / 1 LED, green; Operating mode / 5 LED, white
Teach function
Electrical connection
Plug connection
1 x M12; coding: A; contacts: 5
Electrical data
Operating voltage
18...30 DC; ("supply class 2" according to cULus) V
Electricity consumption
< 60 mA
Protection class
III
Standby delay time
< 0,3 s
Wavelength
630 nm
Typical lifetime
50000 h
Reverse polarity protection
Environmental conditions
Ambient temperature
0...60 °C
Storage temperature
-10...65 °C
Degree of protection
IP 65; IP 67
Field of application
Application
Industrial applications / factory automation
Inputs
Inputs
Laser On / Off
Number of digital inputs
1
Inputs / Outputs
Number of inputs and outputs
Number of digital inputs: 1; Number of digital outputs: 2
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Smart Sensor - SSP 4.1.1 / Measuring and Switching Sensor, 1 channel; Common - I&D / Identification and Diagnosis; Extension / Sensor control; Extension / Teach two point; Function / Locator; Function / ProductURI
Required master port class
A
Min. process cycle time
3,2 ms
IO-Link process data (cyclic)
Function / bit length; Process value / 16; Device status / 4; Binary switching information / 2