Further information for Ifm Electronic NT5001 - Metal housing Ø 6 5 Cable
Metal housing, Ø 6.5, Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW, ATEX approval, Group II, category 1D, Group II, category 1G/2G, Cable, Sensing range 1 mm [f]
Nominal voltage: 8.2 DC; (1kΩ) V
Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW
Output function: Normally closed
Current rating: < 30; when used outside the hazardous area mA
Length: 30 mm
Mounting: flush mountable
Sensing range: 1 mm
Switching frequency: 2000 Hz
Connection: PVC cable / 2 m; 2 x 0.14 mm²
Housing materials: Brass special coating; active face: PBT
Ambient temperature: -20...80 °C
Protection: IP 67
Marking of the unit: ExII 1G Ex ia IIC T6 Ga Ta: -20…70° C ExII 1G Ex ia IIC T5 Ga Ta: -20…80° C ExII 1D Ex ia IIIC T90° C Da Ta: -20…70° C ExII 1D Ex ia IIIC T100° C Da Ta: -20…80° C
Accessories (to be ordered separately): Mounting accessories
Type: NT5001