II 1D Ex ia IIIC T200 90°C Da; II 2G Ex ia IIB T6 Gb
EMC
EN 60947-5-6
Shock and vibration stress
30 g (11 ms) / 10-55 Hz (1 mm)
MTTF
2825 years
Detection range
Real switching distance Sr
20 ± 10 % mm
Displays / controls
Indication
Switching state / 1 x LED, yellow
Electrical connection - Plug
Plug connection
1 x M12; Coding: A; Contacts: 5, gold-plated; Locking: Brass, white bronze-coated
Electrical data
Switching amplifier
Connection to certified intrinsically safe circuits with maximum values: U = 15 V / I = 50 mA / P = 120 mW
Nominal voltage DC
8,2; (1kΩ) V
Supply voltage DC
7.5...30; (when used outside Ex area) V
Electricity consumption
< 1; (blocking; conducting: > 2.1) mA
Protection class
III
Connection to switching amplifier
Environmental conditions
Ambient temperature
-20...70 °C
Degree of protection
IP 67
Field of application
Special feature
Gold-plated contacts
Application
For applications in hazardous explosive areas
Mechanical data
Mounting type
Flush-mountable
Materials
housing: PPE; active surface: PPE orange; angled piece: PPS; mounting adapter: PPS black; screw: zinc-plated steel
Outputs
Continuous current rating of switching output DC
30; (when used outside Ex area) mA
Switching frequency DC
200 Hz
Product features
Electrical version
NAMUR
Output function
Breaker contact
Switching distance
20 mm
Housing
rectangular
Dimensions
40 x 40 x 66 mm
Remarks
Remarks
5 layers of active switching zone selectable
Safety ratings
Max. self-capacitance
250 nF
Max. self-inductance
450 µH
Induktiver Sensor, 40 x 40 x 66 mm, Schaltabstand 20 mm bündig einbaubar, Öffner, DC, NAMUR, M12 Steckverbindung, IP 67, 2-Leiter, Umgebungstemperatur -20...70 °C, Schaltfrequenz 200 Hz