II 1G Ex ia IIC T6 Ga Ta -20...70°C; II 1G Ex ia IIC T5 Ga Ta -20...80°C; II 1D Ex ia IIIC T200 90°C Da Ta: -20...70°C; II 1D Ex ia IIIC T200 100°C Da Ta: -20...80°C
EMC
EN 60947-5-6
Shock and vibration stress
30 g (11 ms) / 10-55 Hz (1 mm)
MTTF
4736 years
Detection range
Real switching distance Sr
4 ± 10 % mm
Electrical connection
Cable
6 m, PVC; 2 x 0.34 mm²
Electrical data
Switching amplifier
Connection to certified intrinsically safe circuits with maximum values: U = 15 V / I = 50 mA / P = 120 mW
Nominal voltage DC
8,2; (1kΩ) V
Supply voltage DC
7.5...30; (when used outside Ex area) V
Electricity consumption
< 1; (blocking; conducting: > 2.1) mA
Protection class
III
Connection to switching amplifier
Environmental conditions
Ambient temperature
-20...80 °C
Degree of protection
IP 67
Field of application
Application
For applications in hazardous explosive areas
Mechanical data
Mounting type
not flush-mountable
Thread designation
M12 x 1
Materials
Brass specially coated; active surface: PC
Outputs
Continuous current rating of switching output DC
30; (when used outside Ex area) mA
Switching frequency DC
1500 Hz
Product features
Electrical version
NAMUR
Output function
Breaker contact
Switching distance
4 mm
Housing
Threaded design
Dimensions
M12 x 1 / L = 30 mm
Safety ratings
Max. self-capacitance
141 nF
Max. self-inductance
134 µH
Inductive sensor, Metal thread, M12 x 1, Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW, ATEX approval, Group II, category 1D, Group II, category 1G/2G, Cable, Sensing range 4 mm [nf]
Nominal voltage: 8.2 DC; (1kΩ) V
Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW
Output function: Normally closed
Current rating: < 30; when used outside the hazardous area mA
Length: 30 mm
Mounting: non-flush mountable
Sensing range: 4 mm
Switching frequency: 1500 Hz
Connection: PVC cable / 6 m; 2 x 0.34 mm²
Housing materials: Brass special coating; active face: PC
Ambient temperature: -20...80 °C
Protection: IP 67
Marking of the unit: ExII 1G Ex ia IIC T6 Ga Ta: -20…70° C ExII 1G Ex ia IIC T5 Ga Ta: -20…80° C ExII 1D Ex ia IIIC T90° C Da Ta: -20…70° C ExII 1D Ex ia IIIC T100° C Da Ta: -20…80° C
Accessories (to be ordered separately): Mounting accessories