| Approvals / tests |
| EMC | EN 61000-4-2 / 4 kV CD / 8 kV AD; EN 61000-4-3 / 10 V/m; EN 61000-4-4 / 2 kV; EN 61000-4-6 / 10 V/m; EN 61000-4-8 / 30 A/m; EN 55011 / 0 Class B |
| Shock resistance | DIN EN 60068-2-27 / 30 g 11 ms half-sine; 3 shocks in each direction of the 3 coordinate axes |
| Rapid temperature change | EN 60068-2-14 Na / TA = -10 °C; TB = 70 °C; t1 = 60 min; t2 = < 10 s; 20 cycles |
| Salt spray test | EN 60068-2-52 Kb / severity level 5 (4 test cycles) |
| MTTF | 3718 years |
| Detection range |
| Real switching distance Sr | 1,7 ± 10 % mm |
| Working distance | 1,38 mm |
| Electrical connection |
| Cable | 2 m, PUR |
| Electrical data |
| Operating voltage | 10...30 DC V |
| Electricity consumption | < 40 mA |
| Protection class | III |
| Reverse polarity protection | |
| Environmental conditions |
| Ambient temperature | -32...85 °C |
| Degree of protection | IP 65; IP 68; IP 69K |
| Field of application |
| Operating principle | Hall sensor |
| Mechanical data |
| Materials | Brass; PA; O-ring: FKM |
| Tightening moment | 7 Nm |
| Gear module | 1,25 mm |
| Shaft length | 45 mm |
| Outputs |
| Max. voltage drop switching output DC | 1 V |
| Max. residual current | 0.1 mA |
| Continuous current rating of switching output DC | 50 mA |
| Short-term current rating of switching output | 50 mA |
| Switching frequency DC | 1...15000 Hz |
| Short-circuit protection | |
| Overload resistant | |
| Product features |
| Electrical version | PNP |
| Output function | Normally open contact |
| Switching distance | 1.7; (The use of gears with different module affects switching distance and phase position.) mm |
| Dimensions | Ø 15 / L = 64,5 mm |
Drehzahlsensor, Ø 15 / L = 64,5 mm, PNP, Schließer, 1,7 mm, 2 m PUR-Kabel