Further information for ifm Electronic MR0113 cylinder sensor Reed 3,8 mT
Accessories
Scope of delivery
Memory gum: 1; Cable clip: 1
Accuracy / Deviations
Hysteresis
1 mm
Repeatability
-0,2...0,2 mm
Approvals / tests
EMC
EN 61000-4-2 ESD / CD / 8 kV AD; EN 61000-4-3 RF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-5 Surge / 2 kV line to line, Ri: 2 Ohm; EN 61000-4-6 RF conducted / 10 V; EN 55011 / Class B
MTTF
11302 years
UL approval
UL Listing Number / C004
Detection range
Trigger sensitivity
3,8 mT
Speed over crossing
10 m/s
Displays / controls
Indication
Switching state / 1 x LED, yellow
Electrical connection
Required fuse rating
Miniature fuse according to IEC60127-2 Sheet 1; ≤ 0.175 A; fast
Electrical connection - Plug
Cable
0.3 m, PUR
Plug connection
1 x M8; coding: A; contacts: 3; locking: snap-screw connection
Electrical data
Operating voltage
5...50 AC / 5...60 DC V
Protection class
III
Reverse polarity protection
Reverse polarity protected
Environmental conditions
Ambient temperature
-25...70 °C
Degree of protection
IP 65; IP 67
Field of application
Operating principle
Reed contact
Mechanical data
Mounting type
Flush-mountable
Cylinder design
T-slot cylinder
Materials
PA; Mounting eccentric: stainless steel
Outputs
Max. voltage drop switching output DC
5 V
Max. voltage drop switching output AC
5 V
Continuous current rating of switching output AC
100; (External protection circuit for inductive load (valve, contactor etc.) required.) mA
Continuous current rating of switching output DC
100; (External protection circuit for inductive load (valve, contactor etc.) required.) mA
Switching frequency AC
1000 Hz
Switching frequency DC
1000 Hz
Max. switching power
10 W
Short-circuit protection
Short-circuit-proof
Overload resistant
Product features
Electrical version
PNP/NPN
Output function
Normally open contact
Dimensions
30,5 x 5 x 6,5 mm
Remarks
Remarks
In case of reverse polarity in DC operation, no LED function.; Supply voltage "supply class 2" according to cULus
Response times
Max. drop time
0,1 ms
Max. switching time including bounce
0,6 ms
Zylindersensor mit Reed-Kontakt, 30,5 x 5 x 6,5 mm, Ansprechempfindlichkeit 3,8 mT, Verpolungsschutz ja, Kurzschlussschutz nein, Überlastfest nein, Schließer, AC/DC, PNP/NPN, 0,3 m PUR-Kabel, M8 Steckverbindung, IP 65, IP 67, 2-Leiter, Schaltfrequenz 1000 Hz AC / 1000 Hz DC