Further information for ifm Electronic MK5314 cylinder sensor GMR 2.8 mT PNP
Accuracy / Deviations
Hysteresis
1,5 mm
Repeatability
< 0,2 mm
Approvals / tests
EMC
EN 61000-4-2 ESD / - CD / 8 kV AD; EN 61000-4-3 Radiated HF / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 Conducted HF / 10 V; EN 55011 / Class B
MTTF
3731 years
UL approval
Ta / -25...75 °C; Enclosure type / Type 1; Power supply / Limited Voltage/Current (Marking Class 2); Certification number UL / C008; File number UL / E174191
10...30 DC; ("supply class 2" according to cULus) V
Electricity consumption
< 10 mA
Protection class
III
Max. standby delay time
30 ms
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...85 °C
Degree of protection
IP 65; IP 67
Field of application
Operating principle
GMR cell
Mechanical data
Mounting type
Flush-mountable
Cylinder design
C-slot cylinder
Materials
Housing: PA; mounting eccentric: stainless steel
Outputs
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
100 mA
Switching frequency DC
10000 Hz
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP
Output function
Normally open contact
Dimensions
26,1 x 2,8 x 5,5 mm
Zylindersensor mit GMR-Zelle, 26,1 x 2,8 x 5,5 mm, Ansprechempfindlichkeit 2,8 mT, Verpolungsschutz ja, Kurzschlussschutz ja, Überlastfest ja, Schließer, DC, PNP, 0,3 m PUR-Kabel, M12 Steckverbindung, IP 65, IP 67, 3-Leiter, Schaltfrequenz 10000 Hz