10...30 DC; ("supply class 2" according to cULus) V
Protection class
III
Max. standby delay time
30 ms
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...85 °C
Degree of protection
IP 65; IP 67
Field of application
Operating principle
GMR cell
Mechanical data
Mounting type
Flush-mountable
Mounting method
Mounting eccentric with combination head slot / internal hexagon SW 1.5
Cylinder design
T-slot cylinder
Materials
Housing: PA; mounting eccentric: stainless steel
Outputs
Max. voltage drop switching output DC
4,5 V
Minimum load current
5 mA
Max. residual current
0,8 mA
Continuous current rating of switching output DC
100 mA
Switching frequency DC
4000 Hz
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP/NPN
Output function
Normally open contact
Dimensions
25,3 x 5 x 6,5 mm
Zylindersensor mit GMR-Zelle, 25,3 x 5 x 6,5 mm, Ansprechempfindlichkeit 2,8 mT, Verpolungsschutz ja, Kurzschlussschutz ja, Überlastfest ja, Schließer, DC, PNP/NPN, 0,3 m PUR-Kabel, M8 Steckverbindung, IP 65, IP 67, 2-Leiter, Schaltfrequenz 4000 Hz