Further information for ifm Electronic MK502A cylinder sensor AMR 2mT
Accessories
Scope of delivery
Memory gum: 1; Cable clip: 1
Accuracy / Deviations
Hysteresis
1 mm
Repeatability
< 0,2 mm
Approvals / tests
Approval
BVS 09 ATEX E164; IECEx BVS 09.0065
ATEX equipment marking
II 1G Ex ia IIC T4 Ga; II 1D Ex ia IIIC T135°C Da
EMC
EN 61000-4-2 ESD / - kV CD / 8 kV AD; EN 61000-4-3 Radiated HF / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 Conducted HF / 10 V; EN 55011 Emission / Class B
MTTF
2142 years
Detection range
Trigger sensitivity
2 mT
Speed over crossing
> 10 m/s
Displays / controls
Indication
Switching state / 1 x LED, yellow
Electrical connection
Cable
6 m, PVC; 2 x 0.14 mm²
Electrical data
Switching amplifier
Connection to certified intrinsically safe circuits with maximum values: U = 15 V / I = 50 mA / P = 120 mW
Nominal voltage DC
8,2 V
Electricity consumption
Target not detected: ≤ 1; Target detected: ≥ 2.2 mA
Protection class
III
Connection to switching amplifier
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...70 °C
Degree of protection
IP 65; IP 67
Field of application
Operating principle
AMR cell
Mechanical data
Mounting type
Flush-mountable
Mounting method
Mounting eccentric with combination head slot / internal hexagon SW 1.5
Cylinder design
T-slot cylinder
Materials
Housing: PA; mounting eccentric: stainless steel
Outputs
Switching frequency DC
2000 Hz
Short-circuit protection
Overload resistant
Product features
Electrical version
NAMUR
Output function
Normally open contact
Dimensions
25,3 x 5 x 6,5 mm
Safety ratings
Max. self-capacitance
140 nF
Max. self-inductance
400 µH
Zylindersensor mit AMR-Zelle, 25,3 x 5 x 6,5 mm, Ansprechempfindlichkeit 2 mT, Verpolungsschutz ja, Kurzschlussschutz ja, Überlastfest ja, Schließer, DC, NAMUR, 6 m PVC-Kabel, IP 65, IP 67, 2-Leiter, Schaltfrequenz 2000 Hz