| Accuracy / Deviations |
| Repeatability | ± 5 mm |
| Measurement error | ± 7 mm |
| Offset error | 5 mm |
| Resolution | 1 mm |
| Zero signal voltage | 0 V |
| Zero signal current | 4 mA |
| Full signal voltage | 10 V |
| Full signal current | 20 mA |
| Temperature influence per 10 K | ± 0,2 % |
| Approvals / tests |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 / in closed metal enclosure; DIN EN 61000-6-4 / in plastic or open metal enclosure |
| Shock resistance | DIN EN 60068-2-27 / 50 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m |
| Vibration resistance | DIN EN 60068-2-6 / 5 g (10...2000 Hz) / 1 g (5...200 Hz) with reference bar 0.5 m |
| MTTF | 239 years |
| UL approval | File Number UL / E355663 |
| Electrical connection |
| Plug connection | 1 x M12; Coding: A; Contacts: 4, gold-plated |
| Electrical data |
| Operating voltage | 18...30 DC V |
| Electricity consumption | < 25 mA |
| Protection class | III |
| Standby delay time | < 3 s |
| Measurement principle | Guided microwave |
| Reverse polarity protection | |
| Environmental conditions |
| Ambient temperature | -25...60 °C |
| Storage temperature | -40...85 °C |
| Degree of protection | IP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68) |
| Field of application |
| Special feature | Gold-plated contacts |
| Media | liquid media |
| Dielectric constant of medium | ≥ 1.8; (for media with DK 1.8...5 (e.g. oils) a coaxial tube is required for operation) |
| Recommended media | Water; water-based media; oils; oil-based media |
| Not suitable for | See instruction manual, chapter "Intended use". |
| Medium temperature | -25...80; (90 < 1 h) °C |
| Container pressure | -1...16 bar / -0.1...1.6 MPa |
| Interfaces |
| Communication interface | IO-Link |
| Transmission type | COM2 (38.4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Required master port class | A |
| Analog process data | 1 |
| Min. process cycle time | 2,3 ms |
| Supported DeviceIDs | Operation mode / DeviceID; default / 685 |
| SIO mode | |
| Measurement / adjustment range |
| Active area A | L-40; (when set to oil and oil-based media: L-60) mm |
| Inactive zone I1 / I2 | 30 / 10; (at setting for oil and oil-based media: 30 / 30) mm |
| Measurement frequency | 4 Hz |
| Mechanical data |
| Dimensions | Ø 50 / L = 86 mm |
| Materials | 1.4301 (stainless steel / 304); 1.4404 (stainless steel / 316L); FKM; PEI |
| Materials in contact with the medium | 1.4305 (stainless steel / 303); sensor connection: 1.4435 (stainless steel / 316L); PTFE; FKM; seal: NBR reinforced with fibres |
| Outputs |
| Total number of outputs | 2 |
| Output signal | Analog signal; IO-Link |
| Electrical version | PNP |
| Number of digital outputs | 1 |
| Number of analogue outputs | 1 |
| Analog output current | 4...20, reversible mA |
| Max. load | 500 Ω |
| Analog output voltage | 0...10, reversible V |
| Minimum load resistance | 2000 Ω |
| Short-circuit protection type | thermal, timed |
| Short-circuit protection | |
| Overload resistant | |
| Product features |
| Number of inputs and outputs | Number of digital outputs: 1; Number of analog outputs: 1 |
| Factory setting | Water-based media; rod length L= 400 mm |
| Rod length L | 100...1600 mm |
| Process connection | G 3/4 male thread |
Electronic level sensor, PNP, analog signal, IO-Link, medium temperature -25...80, (90 < 1 h) °C, G 3/4 external thread, plug connection