| Accuracy / Deviations |
| Accuracy | ± 2 mm |
| Resolution | 1 mm |
| Zero signal current | 3,8 mA |
| Full signal current | 20,5 mA |
| Temperature influence per 10 K | ± 1 mm |
| Approvals / tests |
| EMC | DIN EN 61326-1 / Group 1: Class A (IO-Link active); B (IO-Link not active, with analogue and switching outputs) |
| Shock resistance | DIN EN 60068-2-27 / 50 g (11 ms) / 20 g (6 ms) |
| Vibration resistance | IEC 61298-3 / 2 g (10...1000 Hz) |
| MTTF | 330 years |
| Electrical connection |
| Plug connection | 1 x M12; Coding: A; Contacts: 4, gold-plated |
| Electrical data |
| Operating voltage | 18...30 DC V |
| Electricity consumption | < 80 mA |
| Protection class | III |
| Standby delay time | < 15 s |
| Measurement principle | FMCW (80 GHz technology); Frequency range 77 - 81 GHz |
| Reverse polarity protection | |
| Environmental conditions |
| Ambient temperature | -40...80 °C |
| Note on ambient temperature | see diagram |
| Storage temperature | -40...90 °C |
| Degree of protection | IP 68; IP 69K |
| Field of application |
| Special feature | Gold-plated contacts |
| Dielectric constant of medium | ≥ 2 |
| Recommended media | Water; water-based media |
| Medium temperature | -40...150; (see diagram) °C |
| Maximum speed of level change | 200 mm/s |
| Compressive strength | 8 bar |
| Note on pressure resistance | 0 bar at medium temperature < -20 C |
| Vacuum tightness | -1000 mbar |
| MAWP for applications according to CRN | 8 bar |
| Radio approval for | EU/RED; United Kingdom; South Korea; USA; Canada; Australia; New Zealand; Vietnam; Singapore; Argentina; Brazil; Japan; Taiwan; South Africa; Mexico |
| Note on radio approval | The list of countries applying the European Radio Equipment Directive 2014/53/EU is available under "Downloads". |
| Interfaces |
| Communication interface | IO-Link |
| Transmission type | COM2 (38.4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 3.1 / Measuring Sensor; Common - I&D / Identification and Diagnosis; Function / Multiple switching signal |
| Required master port class | A |
| Analog process data | 1 |
| Process data binary | 2 |
| Min. process cycle time | 6 ms |
| Supported DeviceIDs | Operating mode / DeviceID; default / 1324 |
| SIO mode | |
| Measurement / adjustment range |
| Measuring range | 10; (see diagram) m |
| Measurement frequency | > 3 Hz |
| Mechanical data |
| Materials | 1.4404 (stainless steel / 316L); PA; FKM; FVMQ |
| Materials in contact with the medium | PTFE; EPDM |
| Surface roughness Ra/Rz of medium-contacting surfaces | Ra < 0,76 µm |
| Outputs |
| Total number of outputs | 2 |
| Output signal | Switching signal; Analogue signal; IO-Link |
| Electrical version | PNP/NPN |
| Number of digital outputs | 1; (2 configurable) |
| Output function | Normally open contact (NO) / Normally closed contact (NC); (configurable) |
| Max. voltage drop switching output DC | 2,5 V |
| Continuous current rating of switching output DC | 50 mA |
| Number of analogue outputs | 1 |
| Analog output current | 4...20, reversible; (scalable) mA |
| Max. load | 43,5 * (Ub – 18) + 600 Ω Ω |
| Short-circuit protection type | timed |
| Short-circuit protection | |
| Overload resistant | |
| Product features |
| Number of inputs and outputs | Number of digital outputs: 1; Number of analog outputs: 1 |
| Process connection | G 1 Aseptoflex Vario |
| Remarks |
| Notes | For initial commissioning, an IO-Link master and parameterization software (e.g. moneo or LR DEVICE) are required. |
| Response times |
| Response time | 330 ms |
Elektronischer Füllstandsensor, Funkzulassung für EU/RED, Großbritannien, Süd-Korea, USA, Kanada, Australien, Neuseeland, Vietnam, Singapur, Argentinien, Brasilien, Japan, Taiwan, Südafrika, PNP/NPN, Schaltsignal, Analogsignal, IO-Link, Mediumtemperatur -40...150, (siehe Diagramm) °C, Druckfestigkeit 8 bar, G 1 Aseptoflex Vario, Steckverbindung