Further information for ifm Electronic LW2120 level sensor PNP/NPN IO-Link
Accuracy / Deviations
Accuracy
± 2 mm
Resolution
1 mm
Zero signal current
3,8 mA
Full signal current
20,5 mA
Temperature influence per 10 K
± 1 mm
Approvals / tests
EMC
DIN EN 61326-1 / Group 1: Class A (IO-Link active); B (IO-Link not active, with analogue and switching outputs)
Shock resistance
DIN EN 60068-2-27 / 50 g (11 ms) / 20 g (6 ms)
Vibration resistance
IEC 61298-3 / 2 g (10...1000 Hz)
MTTF
330 years
Electrical connection
Plug connection
1 x M12; Coding: A; Contacts: 4, gold-plated
Electrical data
Operating voltage
18...30 DC V
Electricity consumption
< 80 mA
Protection class
III
Standby delay time
< 15 s
Measurement principle
FMCW (80 GHz technology); Frequency range 77 - 81 GHz
Reverse polarity protection
Environmental conditions
Ambient temperature
-40...80 °C
Note on ambient temperature
see diagram
Storage temperature
-40...90 °C
Degree of protection
IP 68; IP 69K
Field of application
Special feature
Gold-plated contacts
Dielectric constant of medium
≥ 2
Recommended media
Water; water-based media
Process temperature
-40...150; (see diagram and note under Remarks) °C
Maximum speed of level change
200 mm/s
Compressive strength
8 bar
Note on pressure resistance
0 bar at medium temperature < -20 C
Vacuum tightness
-1000 mbar
MAWP for applications according to CRN
8 bar
Radio approval for
EU/RED; United Kingdom; South Korea; USA; Canada; Australia; New Zealand; Vietnam; Singapore; Argentina; Brazil; Japan; Taiwan; South Africa; Mexico
Note on radio approval
The list of countries applying the European Radio Equipment Directive 2014/53/EU is available under "Downloads".
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Smart Sensor - SSP 3.1 / Measuring Sensor; Common - I&D / Identification and Diagnosis; Function / Multiple switching signal
Required master port class
A
Analog process data
1
Process data binary
2
Min. process cycle time
6 ms
Supported DeviceIDs
Operation mode / DeviceID; default / 1611
SIO mode
Measurement / adjustment range
Measuring range
10; (see diagram) m
Measurement frequency
> 3 Hz
Mechanical data
Materials
1.4404 (stainless steel / 316L); PA; FKM; FVMQ
Materials in contact with the medium
PTFE; EPDM; FVMQ when used without Aseptoflex-Vario adapter
Surface roughness Ra/Rz of medium-contacting surfaces
Ra < 0,76 µm
Outputs
Total number of outputs
2
Output signal
Switching signal; Analogue signal; IO-Link
Electrical version
PNP/NPN
Number of digital outputs
1; (2 configurable)
Output function
Normally open contact (NO) / Normally closed contact (NC); (configurable)
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
50 mA
Number of analogue outputs
1
Analog output current
4...20, reversible; (scalable) mA
Max. load
43,5 * (Ub – 18) + 600 Ω Ω
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Process connection
G 1 Aseptoflex Vario
Remarks
Notes
For initial commissioning, an IO-Link master and configuration software (e.g. moneo or LR DEVICE) are required.; For high process temperatures: The temperature at the process connection is decisive. The actual medium temperature may be higher.; Use under FDA compliance only in combination with a hygienic adapter
Response times
Response time
330 ms
Elektronischer Füllstandsensor, Funkzulassung für EU/RED, Großbritannien, Süd-Korea, USA, Kanada, Australien, Neuseeland, Vietnam, Singapur, Argentinien, Brasilien, Japan, Taiwan, Südafrika, PNP/NPN, Schaltsignal, Analogsignal, IO-Link, Druckfestigkeit 8 bar, G 1 Aseptoflex Vario, Steckverbindung