| Accuracy / Deviations |
| Repeatability | ± 5 mm |
| Measurement error | ± 7 mm |
| Offset error | 5 mm |
| Resolution | 1 mm |
| Temperature influence per 10 K | ± 0,2 % |
| Approvals / tests |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 / : in closed metal enclosure; DIN EN 61000-6-4 / : in plastic or open metal enclosure |
| Shock resistance | DIN EN 60068-2-27 / 50 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m |
| Vibration resistance | DIN EN 60068-2-6 / 5 g (10...2000 Hz) / 1 g (5...200 Hz) with reference bar 0.5 m |
| MTTF | 242 years |
| UL approval | Certification number UL / H011; File number UL / E174191 |
| Electrical connection - Plug |
| Plug connection | 1 x M12; Coding: A; Contacts: 7, gold-plated |
| Electrical data |
| Operating voltage | 18...30 DC V |
| Electricity consumption | < 25 mA |
| Protection class | III |
| Standby delay time | < 3 s |
| Measurement principle | Guided microwave |
| Reverse polarity protection | |
| Environmental conditions |
| Ambient temperature | -25...60 °C |
| Storage temperature | -40...85 °C |
| Degree of protection | IP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68) |
| Field of application |
| Special feature | Gold-plated contacts |
| Application | for industrial use |
| Media | liquid media |
| Dielectric constant of medium | ≥ 1.8; (for media with DK 1.8...5 (e.g. oils) a coaxial tube is required for operation) |
| Recommended media | Water; water-based media; oils; oil-based media |
| Process temperature | -25...80; (90 < 1 h ; see note under Remarks) °C |
| Compressive strength | 16 bar / 1.6 MPa |
| Vacuum tightness | -1000 mbar / -0.1 MPa |
| Interfaces |
| Communication interface | IO-Link |
| Transmission type | COM2 (38.4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 3.1 / Measuring Sensor; Common - I&D / Identification and Diagnosis |
| Required master port class | A |
| Analog process data | 3 |
| Process data binary | 4 |
| Min. process cycle time | 3,2 ms |
| Supported DeviceIDs | Operating mode / DeviceID; default / 908 |
| SIO mode | |
| Measurement / adjustment range |
| Active area A | L-40; (when set to oil and oil-based media: L-60) mm |
| Inactive zone I1 / I2 | 30 / 10; (at setting for oil and oil-based media: 30 / 30) mm |
| Measurement frequency | 4 Hz |
| Switching point SP | 15...L-30 mm |
| Switching point SP note | when set to oil and oil-based media: 35...L-30 |
| Reverse switch point rP | 10... L-35 mm |
| Note on reverse switching point rP | when set to oil and oil-based media: 30...L-35 |
| In steps of | 5 mm |
| Hysteresis | > 5 mm |
| Mechanical data |
| Dimensions | Ø 50 / L = 86 mm |
| Materials | 1.4301 (stainless steel / 304); 1.4404 (stainless steel / 316L); FKM; PEI |
| Materials in contact with the medium | 1.4305 (stainless steel / 303); sensor connection: 1.4435 (stainless steel / 316L); PTFE; FKM; seal: NBR reinforced with fibres |
| Outputs |
| Total number of outputs | 4 |
| Output signal | switching signal; IO-Link |
| Electrical version | PNP/NPN |
| Number of digital outputs | 4 |
| Output function | Normally open contact (NO) / Normally closed contact (NC); (configurable) |
| Max. voltage drop switching output DC | 2,5 V |
| Continuous current rating of switching output DC | 200 mA |
| Short-circuit protection type | timed |
| Short-circuit protection | |
| Overload resistant | |
| Product features |
| Number of inputs and outputs | Number of digital outputs: 4 |
| Rod length L | 100...2000 mm |
| Process connection | threaded connection G 3/4 male thread |
| Remarks |
| Notes | For high process temperatures: The relevant temperature is at the process connection. The actual medium temperature may be higher. |
Elektronischer Füllstandsensor, PNP/NPN, Schaltsignal, IO-Link, Stablänge L 100...2000 mm, Druckfestigkeit 16 bar, G 3/4 Außengewinde, Steckverbindung