Further information for Ifm Electronic LR7000 - Electronic level sensor Connector
Accuracy / Deviations
Repeatability
± 5 mm
Measurement error
± 7 mm
Offset error
5 mm
Resolution
1 mm
Temperature influence per 10 K
± 0,2 %
Approvals / tests
EMC
DIN EN 61000-6-2; DIN EN 61000-6-3 / in closed metal enclosure; DIN EN 61000-6-4 / in plastic or open metal enclosure
Shock resistance
DIN EN 60068-2-27 / 50 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m
Vibration resistance
DIN EN 60068-2-6 / 5 g (10...2000 Hz) / 1 g (5...200 Hz) with reference bar 0.5 m
MTTF
233 years
UL approval
Certification number UL / H007; File number UL / E174191
Displays / controls
Indication
Display unit / 3 x LED, green; Switching state / 2 x LED, yellow; Fill level / alphanumeric display, 4-digit; Parameterization / alphanumeric display, 4-digit
Electrical connection
Plug connection
1 x M12; Coding: A; Contacts: 4, gold-plated
Electrical data
Operating voltage
18...30 DC V
Electricity consumption
< 30 mA
Protection class
III
Standby delay time
< 3 s
Measurement principle
Guided microwave
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...60 °C
Storage temperature
-40...85 °C
Degree of protection
IP 67
Field of application
Special feature
Gold-plated contacts
Application
for industrial use
Media
liquid media
Dielectric constant of medium
≥ 1.8; (for media with DK 1.8...5 (e.g. oils) a coaxial tube is required for operation)
Recommended media
Water; water-based media; oils; oil-based media
Not suitable for
See instruction manual, chapter "Intended use".
Process temperature
-25...80; (90 < 1 h ; see note under Remarks) °C
Compressive strength
16 bar / 1.6 MPa
Vacuum tightness
-1000 mbar / -0.1 MPa
MAWP for applications according to CRN
16 bar
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9 CDV
Required master port class
A
Analog process data
1
Process data binary
2
Min. process cycle time
2,3 ms
Supported DeviceIDs
Operation mode / DeviceID; default / 8
SIO mode
Measurement / adjustment range
Active area A
L-40; (when set to oil and oil-based media: L-60) mm
Inactive zone I1 / I2
30 / 10; (at setting for oil and oil-based media: 30 / 30) mm
Normally open contact (NO) / Normally closed contact (NC); (configurable)
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
200 mA
Short-circuit protection type
thermal, timed
Short-circuit protection
Overload resistant
Product features
Number of inputs and outputs
Number of digital outputs: 2
Rod length L
100...1600 mm
Process connection
threaded connection G 3/4 male thread
Remarks
Notes
Please refer to the technical note under "Downloads"; For high process temperatures: The relevant temperature is at the process connection. The actual medium temperature may be higher.
Electronic level sensor, DC PNP, Guided wave radar, Freely rotatable housing 360°, Connector, 4-digit alphanumeric display, 2 switching outputs, 4-digit alphanumeric display
Application: Hydrous coolants, oils, oil-based media, water, media similar to water
Operating voltage: 18...30 V DC
Electrical design: DC PNP
Output function: 2 x normally open / closed programmable
Current rating: 200 mA
Probe length L: 100...1600 mm
Active range A: L-40 (L-60) mm
Connection: M12 connector (according to EN 61076-2-101)
Housing materials: stainless steel (304S15); FKM; PBT; PC; PEI; TPE / V; PTFE
Materials (wetted parts): stainless steel (303S22); probe connection: stainless steel 316L / 1.4435; PTFE; FKM; sealing: Tesnit
Medium temperature: 0...80 (90 < 1 h) °C
Ambient temperature: 0...60 °C
Protection: IP 67
Display: Display unit: 3 x LED green ; Switching status: 2 x LED yellow ; Level: 4-digit alphanumeric display ; Programming: 4-digit alphanumeric display
Accessories (to be ordered separately): Socket, Mounting accessories