| Accuracy / Deviations |
| Accuracy | 1,5 K |
| Resolution | 0,1 K |
| Response dynamics T09 | 240 s |
| Approvals / tests |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 / in closed metal enclosure; DIN EN 61000-6-4 / in plastic or open metal enclosure |
| Shock resistance | DIN EN 60068-2-27 / 12 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 / 5 g (10...2000 Hz) |
| MTTF | 433 years |
| UL approval | UL approval number / H013; UL file number / E174191 |
| Displays / controls |
| Indication | Operation / LED, green; Switching state / LED, yellow |
| Control elements | inductive programming button |
| Electrical connection |
| Plug connection | 1 x M12; Coding: A; Contacts: 4, gold-plated |
| Electrical data |
| Operating voltage | 9.6...35 DC; (IO-Link: 18...30 DC) V |
| Electricity consumption | < 15 mA |
| Protection class | III |
| Standby delay time | < 1 s |
| Measurement principle | Capacitive |
| Reverse polarity protection | |
| Environmental conditions |
| Ambient temperature | -25...85 °C |
| Storage temperature | -25...85 °C |
| Degree of protection | IP 68; IP 69K; (7 days / 3 m water depth / 0.3 bar: IP 68) |
| Field of application |
| Special feature | Gold-plated contacts |
| Media | liquid media |
| Dielectric constant of medium | > 1,8 |
| Recommended media | Water; water-based media; oils; oil-based media |
| Not suitable for | See operating manual, chapter "Intended use". |
| Medium temperature | -25...85 °C |
| Compressive strength | 0.5 bar / 0.05 MPa |
| Vacuum tightness | -500 mbar |
| Interfaces |
| Communication interface | IO-Link |
| Transmission type | COM2 (38.4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Common - I&D / Identification and Diagnosis; Function / Measurement data, standard resolution |
| Required master port class | A |
| Analog process data | 5 |
| Process data binary | 2 |
| Min. process cycle time | 4,5 ms |
| Supported DeviceIDs | Operating mode / DeviceID; default / 1053 |
| SIO mode | |
| Measurement / adjustment range |
| Active area A | 28 mm |
| Measuring range | -25...85 °C |
| Mechanical data |
| Materials | PP reinforced with fibres |
| Materials in contact with the medium | PP |
| Rod diameter | 16 mm |
| Outputs |
| Total number of outputs | 2 |
| Output signal | switching signal; IO-Link |
| Electrical version | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | Normally open contact (NO) / Normally closed contact (NC); (configurable) |
| Max. voltage drop switching output DC | 2,5 V |
| Continuous current rating of switching output DC | 100 mA |
| Short-circuit protection type | timed |
| Short-circuit protection | |
| Overload resistant | |
| Product features |
| Number of inputs and outputs | Number of digital outputs: 2 |
| Factory setting | water-based media |
| Rod length L | 132 mm |
| Response times |
| Response time | < 0,3 s |
Binärer Füllstandsensor, PNP/NPN, Schaltsignal, IO-Link, Stablänge L 132 mm, Mediumtemperatur -25...85 °C, Druckfestigkeit 0,5 bar, Steckverbindung