Further information for Ifm Electronic LDP100 - Optical particle monitor Connector
Accuracy / Deviations
Accuracy
± 1; (atomic number)
Approvals / tests
MTTF
97 years
Printer directive
Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request
Data storage
Memory size
3000 data sets
Displays / controls
Indication
1 LED, green Power; 1 LED, red Alarm; LC display, displayed value corresponds to cleanliness grade according to ISO 4406:21 and SAE AS4059F; NAS 1638 referenced, see instruction manual
Number of digital outputs: 1; Number of analog outputs: 1
Process connection
Threaded connection M16 x 2 male thread Minimess
Software / Programming
Parameterization options
Via buttons, PC or digital I/O
Optical particle monitor, DC, Measuring principle: light extinction principle, Cleanliness level to ISO 4406: 99 / SAE AS4059E , Size channels [µm]: 4, 6, 14, 21, CAN interface, Connector, Out 1: analogue (4...20 mA); Out 2: switching output (open collector output)
Application: Mineral oils (e.g. HLP), ester oils (e.g. HEES), biodegradable oils (e.g. HETG)
Operating voltage: 9...33 V DC
Electrical design: DC
Output function: 4...20 mA (can be configured); digital alarm output
Current rating: 500 mA
Connection: M12 connector
Materials (wetted parts): stainless steel 420 / 1.4028; sapphire; NBR; chromium
Medium temperature oil: -10...80 °C
Ambient temperature: -10...60 °C
Protection: IP 67
Display: LC display: displayed value conforms to the cleanliness level to ISO 4406: 99 and SAE AS4059E
Accessories (to be ordered separately): Socket, Mounting accessories