Further information for ifm Electronic LDL100 conductivity sensor DC M12
Accuracy / Deviations
Accuracy (within measurement range)
10 % MW ± 25 µS/cm
Drift
0,2 %/K MW %/K
Repeatability
5 % MW ± 25 µS/cm
Long-term stability
1 % MW ± 25 µS/cm
Accuracy
20...50 °C: < ± 0,5 K; -25...150 °C: < ± 1,5 K K
Approvals / tests
EMC
DIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 / 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 / 20 g (10...2000 Hz)
MTTF
172 years
UL approval
File number UL / E364788
Electrical connection
Plug connection
1 x M12 (EN 61067-2-101); coding: A; contacts: 4, gold-plated
Electrical data
Operating voltage
18...30 DC V
Electricity consumption
< 60 mA
Protection class
III
Standby delay time
2 s
Measurement principle
Conductive
Reverse polarity protection
Environmental conditions
Ambient temperature
-40...60 °C
Storage temperature
-40...85 °C
Degree of protection
IP 68; IP 69K; (7 days / 3 m water depth / 0.3 bar: IP 68)
Field of application
Special feature
Gold-plated contacts
Media
Conductive liquid media
Media note
Water; Milk; CIP fluids
Not suitable for
See instruction manual, chapter "Intended use".
Medium temperature
-25...100; (< 1 h: 150) °C
Compressive strength
16 bar / 1.6 MPa
Vacuum tightness
-1000 mbar
MAWP for applications according to CRN
16 bar / 1.6 MPa
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Smart Sensor - SSP 3.1 / Measuring Sensor; Common - I&D / Identification and Diagnosis
Required master port class
A
Analog process data
1
Min. process cycle time
6,4 ms
Supported DeviceIDs
Operation mode / DeviceID; default / 921
SIO mode
Measurement / adjustment range
Measuring range
100...15000 µS/cm
Resolution
1 µS/cm
Mechanical data
Materials
1.4404 (stainless steel / 316L); PEEK; PEI; FKM
Materials in contact with the medium
PEEK; 1.4404 (stainless steel / 316L)
Surface roughness Ra/Rz of medium-contacting surfaces
Ra ≤ 0.8 µm
Outputs
Total number of outputs
1
Output signal
Analog signal; IO-Link
Output function
Scalable analogue output; switchable conductivity / temperature
Number of analogue outputs
1
Analog output current
4...20 mA
Max. load
500 Ω
Product features
Number of inputs and outputs
Number of analog outputs: 1
Process connection
Threaded connection G 1/2 male thread sealing cone
Remarks
Remarks
MW = measured value
Notes
Digital meets analog: Modern IO-Link sensors integrated analogously. With the EIO104, you can realize two analog signals from intelligent IO-Link sensors with multiple process values.
Response times
Response time
< 2; (T09; Damping = 0) s
Konduktiver Leitfähigkeitssensor, Analogausgang, skalierbar, umschaltbar Leitfähigkeit / Temperatur, analog, DC, M12 Steckverbindung, IP 68, IP 69K, (7 Tage / 3 m Wassertiefe / 0,3 bar: IP 68), Umgebungstemperatur -40...60 °C, Druckfestigkeit 16 bar, G 1/2 Außengewinde Dichtkonus, M12 Steckverbindung