EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 HF conducted / 10 V; EN 55011 / Class B; EN 60947-5-2
Active surface: PPE orange; connection module: PPE black; screw: zinc-plated steel
Outputs
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
250 mA
Switching frequency DC
100 Hz
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP
Output function
Normally open contact (NO) / Normally closed contact (NC); (selectable)
Switching distance
30 mm
Housing
rectangular
Dimensions
40 x 40 x 121 mm
Remarks
Remarks
5 layers of active switching zone selectable
Inductive sensor, Rectangular, plastics, DC PNP, Terminals, Sensing range 30 mm [nf]
Operating voltage: 10...36 V DC
Electrical design: DC PNP
Output function: normally open / closed programmable
Current rating: 250 mA
Mounting: non-flush mountable
Sensing range: 30 mm
Switching frequency: 100 Hz
Connection: terminals up to 2.5 mm²
Housing materials: PPE
Ambient temperature: -25...80 °C
Protection: IP 65
Output status indication: LED yellow
Accessories (to be ordered separately): Mounting accessories