EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 HF conducted / 10 V; EN 55011 / Class B; EN 60947-5-2
MTTF
604 years
Embedded software included
Detection range
Real switching distance Sr
20 ± 10 % mm
Working distance
0...16,2 mm
Increased switching distance
Displays / controls
Indication
Switching state / 1 x LED, yellow
Electrical connection
Required fuse rating
Miniature fuse according to IEC60127-2 Sheet 1; ≤ 2 A; fast
Active surface: PPE orange; connection module: PPE black; screw: zinc-plated steel
Outputs
Max. voltage drop switching output DC
6 V
Max. voltage drop switching output AC
6,5 V
Minimum load current
5 mA
Max. residual current
2,5 (250 V AC) / 1,3 (110 V AC) / 0,8 (24 V DC) mA
Continuous current rating of switching output AC
250; (350 (...50 °C)) mA
Continuous current rating of switching output DC
100 mA
Short-term current rating of switching output
2200; (20 ms / 0,5 Hz) mA
Switching frequency AC
20 Hz
Switching frequency DC
55 Hz
Short-circuit protection
Short-circuit-proof
Overload resistant
Product features
Output function
Normally open contact (NO) / Normally closed contact (NC); (selectable)
Switching distance
20 mm
Housing
rectangular
Dimensions
40 x 40 x 121 mm
Remarks
Remarks
Recommendation: After a short circuit, check the device for safe operation. 5 layers of the active switching zone selectable
Inductive sensor, Rectangular, plastics, AC/DC, Terminals, Sensing range 20 mm [nf]
Operating voltage: 20...250 V AC/DC
Electrical design: AC/DC
Output function: normally open / closed programmable
Current rating (continuous): 250 AC / 100 DC; 350 AC (...50 °C) mA
Current rating (peak): î: 2.2 A (20 ms / 0.5 Hz) mA
Mounting: non-flush mountable
Sensing range: 20 mm
Switching frequency: 20 AC / 55 DC Hz
Connection: terminals up to 2.5 mm²
Housing materials: PPE
Ambient temperature: -25...80 °C
Protection: IP 65
Output status indication: LED yellow
Accessories (to be ordered separately): Mounting accessories