EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 RF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-5 Surge / 0.5 kV; EN 61000-4-6 RF conducted / 10 V; EN 55011 / Class B
MTTF
1134 years
UL approval
Ta / 0...40 °C; Enclosure type / Type 1; Power supply / Limited Voltage/Current; UL approval number / A001; UL file number / E174191
Detection range
Real switching distance Sr
10 ± 10 % mm
Working distance
0...8,1 mm
Displays / controls
Indication
Switching state / 4 x LED, yellow
Electrical connection - Plug
Plug connection
1 x M12; coding: A; contacts: 3, gold-plated
Electrical data
Operating voltage
10...30 DC V
Electricity consumption
10 mA
Protection class
II
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...70 °C
Degree of protection
IP 67
Field of application
Special feature
Gold-plated contacts
Application
Industrial applications / factory automation
Mechanical data
Mounting type
Flush-mountable
Thread designation
M30 x 1.5
Materials
Housing: 1.4404 (stainless steel / 316L); active surface: PBT orange; LED window: PEI; mounting nuts: brass, white bronze-coated
Tightening moment
80 Nm
Outputs
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
100 mA
Switching frequency DC
100 Hz
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP
Output function
Normally open contact
Switching distance
10 mm
Housing
Threaded design
Dimensions
M30 x 1,5 / L = 70 mm
Induktiver Sensor, M30 x 1,5 / L = 70 mm, Schaltabstand 10 mm bündig einbaubar, Schließer, DC, PNP, M12 Steckverbindung, IP 67, 3-Leiter, Umgebungstemperatur -25...70 °C, Schaltfrequenz 100 Hz