EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 RF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 RF conducted / 10 V; EN 55011 / Class B
Vibration resistance
EN 60068-2-6 Fc / 20 g (10...3000 Hz) / 50 frequency cycles, 1 octave/minute, in 3 axes
Shock resistance
EN 60068-2-27 Ea / 100 g 11 ms half-sine; 3 shocks in each direction of the 3 coordinate axes
Continuous shock resistance
EN 60068-2-29 Eb / 40 g 6 ms; 4000 shocks in each direction of the 3 coordinate axes
Rapid temperature change
EN 60068-2-14 Na / TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles
MTTF
664 years
UL approval
Ta / -25...70 °C; Enclosure type / Type 1; Power supply / Limited Voltage/Current; UL approval number / A008; UL file number / E174191
Embedded software included
Detection range
Switching point IO-Link
2.4...12.1; (configurable) mm
Measurement range IO-Link
1,3...13 mm
Displays / controls
Indication
Switching state / 4 x LED, yellow; SIO mode; output stage energized / LED, yellow illuminated; IO-Link mode; target in measurement range / LED, yellow illuminated
Electrical connection - Plug
Plug connection
1 x M12; Coding: A; Contacts: 3
Electrical data
Operating voltage
10...30 DC V
Electricity consumption
< 15 mA
Protection class
III
Reverse polarity protection
Environmental conditions
Ambient temperature
-40...85 °C
Degree of protection
IP 65; IP 66; IP 67; IP 68; IP 69K
Interfaces
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9 CDV
Profiles
Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Multiple switching signal; Function / Process data variable; Function / Device diagnosis; Function / Teach channel
Required master port class
A
Min. process cycle time
3 ms
Supported DeviceIDs
Operating mode / DeviceID; default / 791
SIO mode
Mechanical data
Mounting type
Flush-mountable
Thread designation
M30 x 1.5
Materials
Housing: brass white bronze-coated; active surface: PBT orange; LED window: PEI; mounting nuts: brass white bronze-coated
Outputs
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
100 mA
Switching frequency DC
100 Hz
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP/NPN; (configurable)
Output function
Normally open contact (NO) / Normally closed contact (NC); (selectable)
Communication interface
IO-Link
Housing
Threaded design
Dimensions
M30 x 1,5 / L = 65 mm
Induktiver Sensor, M30 x 1,5 / L = 65 mm, Schließer / Öffner, (wählbar), DC, PNP/NPN, M12 Steckverbindung, IP 65, IP 66, IP 67, IP 68, IP 69K, 3-Leiter, Umgebungstemperatur -40...85 °C, Schaltfrequenz 100 Hz