EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 RF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 RF conducted / 10 V; EN 55011 / Class B
MTTF
1844 years
Detection range
Real switching distance Sr
10 ± 10 % mm
Working distance
0...8,1 mm
Displays / controls
Indication
Switching state / 1 x LED, yellow
Electrical connection
Cable
2.05 m, PUR, Ø 4.0 mm; 3 x 0.34 mm²
Electrical data
Operating voltage
10...36 DC V
Electricity consumption
15 mA
Protection class
II
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...80 °C
Degree of protection
IP 67
Mechanical data
Mounting type
Flush-mountable
Thread designation
M30 x 1.5
Materials
Housing: brass, white bronze-coated; active surface: PBT orange; plugs: PEI; mounting nuts: brass, white bronze-coated
Outputs
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
200 mA
Switching frequency DC
250 Hz
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP
Output function
Breaker contact
Switching distance
10 mm
Housing
Threaded design
Dimensions
M30 x 1,5 / L = 65 mm
Inductive sensor, Metal thread, M30 x 1.5, DC PNP, Cable, Sensing range 10 mm [f]
Operating voltage: 10...36 V DC
Electrical design: DC PNP
Output function: Normally closed
Current rating: 250 mA
Length: 81 mm
Mounting: flush mountable
Sensing range: 10 mm
Switching frequency: 250 Hz
Connection: PVC cable / 2 m; 3 x 0.5 mm²
Housing materials: Brass nickel-plated; PBT
Ambient temperature: -25...80 °C
Protection: IP 67
Output status indication: LED yellow
Accessories (to be ordered separately): Mounting accessories