EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 RF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 RF conducted / 10 V; EN 55011 Emission / Class B
MTTF
655 years
UL approval
Ta / -25...70 °C; Enclosure type / Type 1; Voltage supply / Limited Voltage/Current; UL approval number / A005; UL file number / E174191
Embedded software included
Detection range
Real switching distance Sr
8 ± 10 % mm
Working distance
0...6,48 mm
Increased switching distance
Displays / controls
Indication
Switching state / 4 x LED, yellow
Electrical connection - Plug
Plug connection
1 x M12; coding: A; contacts: 3, gold-plated
Electrical data
Operating voltage
10...30 DC V
Electricity consumption
< 20 mA
Protection class
II
Reverse polarity protection
Environmental conditions
Ambient temperature
-40...85 °C
Degree of protection
IP 65; IP 66; IP 67; IP 68; IP 69K
Field of application
Special feature
Gold-plated contacts; increased switching distance; correction factor K=1; magnetic field resistant
Application
Use in welding area
Maximum magnetic field strength
300 mT
Magnetic field resistant
Mechanical data
Mounting type
Flush-mountable
Thread designation
M18 x 1
Materials
Housing: brass with anti-adhesive coating; active surface: LCP black; LED window: PEI; mounting nuts: brass with anti-adhesive coating
Tightening moment
15 Nm
Outputs
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
100 mA
Switching frequency DC
2000 Hz
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP
Output function
Normally open contact
Switching distance
8 mm
Housing
Threaded design
Dimensions
M18 x 1 / L = 45 mm
Induktiver Sensor, M18 x 1 / L = 45 mm, Schaltabstand 8 mm bündig einbaubar, Schließer, DC, PNP, M12 Steckverbindung, IP 65, IP 66, IP 67, IP 68, IP 69K, 3-Leiter, Umgebungstemperatur -40...85 °C, Schaltfrequenz 2000 Hz