EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 RF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-5 Surge / 0.5 kV line to line, Ri: 2 Ohm; EN 61000-4-6 RF conducted / 10 V; EN 55011 / Class B
MTTF
1359 years
UL approval
Ta / 0...40 °C; Enclosure type / Type 1; Power supply / Limited Voltage/Current; File Number UL / E174191
Detection range
Real switching distance Sr
12 ± 10 % mm
Working distance
0...9,7 mm
Increased switching distance
Displays / controls
Indication
Switching state / 4 x 90° LED, yellow; Adjustment aid / 1 x LED, red
Optical alignment aid
Electrical connection
Cable
10 m, PVC, Ø 4.9 mm; 3 x 0.34 mm²
Electrical data
Operating voltage
10...30 DC V
Electricity consumption
< 10 mA
Protection class
II
Reverse polarity protection
Environmental conditions
Ambient temperature
0...100 °C
Degree of protection
IP 68; IP 69K; ("COP")
Field of application
Special feature
Increased switching distance; optical adjustment aid
Application
Use in hygiene areas / Regular cleaning processes
Mechanical data
Mounting type
not flush-mountable
Thread designation
M18 x 1
Materials
1.4404 (stainless steel / 316L); active surface: PEEK
Outputs
Max. voltage drop switching output DC
2,8 V
Minimum load current
2; (only in 2-wire operation) mA
Max. residual current
0.5; (only in 2-wire operation) mA
Continuous current rating of switching output DC
100 mA
Switching frequency DC
300 Hz
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP/NPN
Output function
Normally open contact
Switching distance
12 mm
Housing
Threaded design
Dimensions
M18 x 1 / L = 81 mm
Remarks
Remarks
Compliant with IEC 61131-2 for PLC Type 1
Induktiver Sensor, M18 x 1 / L = 81 mm, Schaltabstand 12 mm nicht bündig einbaubar, Schließer, DC, PNP/NPN, 10 m PVC-Kabel, IP 68, IP 69K, ('COP'), 2-Leiter, 3-Leiter, Umgebungstemperatur 0...100 °C, Schaltfrequenz 300 Hz