EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 RF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 RF conducted / 10 V; EN 55011 / Class B
MTTF
1935 years
UL approval
Ta / -25...70 °C; Enclosure type / Type 1; Power supply / Class 2; File number UL / E174191
Detection range
Real switching distance Sr
12 ± 10 % mm
Working distance
0...9,7 mm
Increased switching distance
Displays / controls
Indication
Switching state / 4 x 90° LED, yellow
Electrical connection - Plug
Plug connection
1 x M8; coding: A; contacts: 3, gold-plated
Electrical data
Operating voltage
10...36 DC V
Electricity consumption
< 10 mA
Protection class
III
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...70 °C
Degree of protection
IP 67; (when screwed)
Field of application
Special feature
Gold-plated contacts; Increased switching gap
Application
Industrial applications / factory automation
Mechanical data
Mounting type
not flush-mountable
Thread designation
M18 x 1
Materials
Cabinet: brass, white bronze coated; active surface: PBT
Outputs
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
100 mA
Switching frequency DC
400 Hz
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP
Output function
Normally open contact
Switching distance
12 mm
Housing
Threaded design
Dimensions
M18 x 1 / L = 52 mm
Inductive sensor, M18 x 1 / L = 52 mm, switching distance 12 mm, non-flush mountable, normally open, DC PNP, M8 connector, IP 67, (when screwed), 3-wire, ambient temperature -25...70 °C, switching frequency 400 Hz