EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 RF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 RF conducted / 10 V; EN 55011 / Class B
MTTF
1806 years
Detection range
Real switching distance Sr
8 ± 10 % mm
Working distance
0...6,5 mm
Displays / controls
Indication
Switching state / 1 x LED, yellow
Electrical connection
Cable
6 m, PUR / PVC; 2 x 0.5 mm²
Electrical data
Operating voltage
10...55 DC V
Protection class
II
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...80 °C
Degree of protection
IP 67
Mechanical data
Mounting type
not flush-mountable
Thread designation
M18 x 1
Materials
Housing: brass white bronze-coated; active surface: PBT orange; plug: PC; mounting nuts: brass white bronze-coated
Outputs
Max. voltage drop switching output DC
4,6 V
Minimum load current
4 mA
Max. residual current
0,8 mA
Continuous current rating of switching output DC
400 mA
Switching frequency DC
300 Hz
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP/NPN
Output function
Normally open contact (NO) / Normally closed contact (NC); (selectable)
Switching distance
8 mm
Housing
Threaded design
Dimensions
M18 x 1 / L = 80 mm
Inductive sensor, M18 x 1 / L = 80 mm, switching distance 8 mm, non-flush mountable, normally open / normally closed (selectable), DC PNP/NPN, 6 m PUR / PVC cable, IP 67, 2-wire, ambient temperature -25...80 °C, switching frequency 300 Hz