EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-5 Surge / 1 kV line to line, Ri: 2 Ohm; EN 61000-4-6 HF conducted / 10 V; EN 55011 Emission / Class B
MTTF
400 years
UL approval
Ta / -25...70 °C; Enclosure type / Type 1; File number UL / E174191
Detection range
Working distance
0...6,48 mm
Increased switching distance
Displays / controls
Indication
Switching state / 1 x LED, red
Electrical connection - Plug
Plug connection
1 x M12; Coding: B; Contacts: 4
Electrical data
Operating voltage
20...140 AC/DC V
Protection class
II
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...70 °C
Degree of protection
IP 67
Field of application
Special feature
Increased switching distance
Mechanical data
Mounting type
Flush-mountable
Thread designation
M18 x 1
Materials
Cabinet: brass, white bronze coated; active surface: PBT
Outputs
Max. voltage drop switching output DC
6 V
Max. voltage drop switching output AC
6,5 V
Minimum load current
5 mA
Max. residual current
1 mA
Continuous current rating of switching output AC
200 mA
Continuous current rating of switching output DC
200 mA
Short-term current rating of switching output
1200; (20ms / 0.5Hz; for UL application: î: 0.9 A (20 ms / 0.5 Hz)) mA
Switching frequency AC
25 Hz
Switching frequency DC
100 Hz
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Output function
Normally open contact
Switching distance
8 mm
Housing
Threaded design
Dimensions
M18 x 1 / L = 53 mm