EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 RF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 RF conducted / 10 V; EN 55011 / Class B
Impact strength
1 J
Vibration resistance
EN 60068-2-6 Fc / 20 g (10...3000 Hz) / 50 frequency cycles, 1 octave/minute, in 3 axes
Shock resistance
EN 60068-2-27 Ea / 100 g 11 ms half-sine; 3 shocks in each direction of the 3 coordinate axes
Continuous shock resistance
EN 60068-2-27 / 40 g 6 ms; 4000 shocks in each direction of the 3 coordinate axes
Inductive sensor, M12 x 1 / L = 45 mm, switching distance 4 mm, flush mountable, normally open, DC PNP, M12 connector, IP 65, IP 66, IP 67, IP 68, IP 69K, 3-wire, ambient temperature 0...100 °C, switching frequency 100 Hz