EN 60068-2-6 Fc / 20 g (10...3000 Hz) / -20...50 °C; 50 frequency cycles, 1 octave/minute, in 3 axes
Shock resistance
EN 60068-2-27 Ea / 100 g 11 ms half-sine; 3 shocks in each direction of the 3 coordinate axes / -40...85 °C
Continuous shock resistance
EN 60068-2-27 / 40 g 6 ms; 4000 shocks in each direction of the 3 coordinate axes / -20...50 °C
Rapid temperature change
EN 60068-2-14 Na / TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles
Salt spray test
EN 60068-2-52 Kb / severity level 5 (4 test cycles)
MTTF
666 years
UL approval
Ta / 0...40 °C; Enclosure type / Type 1; File Number UL / E174191
Detection range
Real switching distance Sr
7 ± 10 % mm
Working distance
0...5,67 mm
Increased switching distance
Displays / controls
Indication
Switching state / 4 x 90° LED, yellow
Electrical connection
Cable
6 m, PUR; burning behaviour according to ECE R118 Rev.2; 3 x 0.5 mm²
Electrical data
Operating voltage
10...60 DC V
Electricity consumption
< 10 mA
Protection class
II
Reverse polarity protection
Environmental conditions
Ambient temperature
-40...85 °C
Degree of protection
IP 67; IP 69K
Field of application
Special feature
Increased switching distance
Application
Use in mobile and harsh applications
Mechanical data
Mounting type
not flush-mountable
Thread designation
M12 x 1
Materials
Enclosure: stainless steel; active surface: natural LCP; LED window: PEI; mounting nuts: brass
Outputs
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
200 mA
Switching frequency DC
300 Hz
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP
Output function
Normally open contact
Switching distance
7 mm
Housing
Threaded design
Dimensions
M12 x 1 / L = 79 mm
Induktiver Sensor, M12 x 1 / L = 79 mm, Schaltabstand 7 mm nicht bündig einbaubar, Schließer, DC, PNP, 6 m PUR-Kabel, IP 67, IP 69K, 3-Leiter, Umgebungstemperatur -40...85 °C, Schaltfrequenz 300 Hz