EN 60068-2-14 Na / TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles
Salt spray test
EN 60068-2-52 Kb / severity level 5 (4 test cycles)
MTTF
1079 years
UL approval
Ta / 0...40 °C; Enclosure type / Type 1; UL certification number / A050; UL file number / E174191
Detection range
Real switching distance Sr
7 ± 10 % mm
Working distance
0...5,67 mm
Increased switching distance
Displays / controls
Indication
Switching state / 4 x 90° LED, yellow
Electrical connection - Plug
Plug connection
1 x M12; coding: A; contacts: 3, gold-plated
Electrical data
Operating voltage
10...60 DC V
Electricity consumption
< 10 mA
Protection class
II
Reverse polarity protection
Environmental conditions
Ambient temperature
-40...85 °C
Degree of protection
IP 67; IP 69K
Field of application
Special feature
Gold-plated contacts; Increased switching gap
Application
Use in mobile and harsh applications
Mechanical data
Mounting type
not flush-mountable
Thread designation
M12 x 1
Materials
Housing: 1.4404 (stainless steel / 316L); active surface: LCP white; LED window: PEI; mounting nuts: brass white bronze-coated
Tightening moment
15 Nm
Outputs
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
200 mA
Switching frequency DC
300 Hz
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP
Output function
Normally open contact
Switching distance
7 mm
Housing
Threaded design
Dimensions
M12 x 1 / L = 70 mm
Remarks
Remarks
Parallel connection not possible
Induktiver Sensor, M12 x 1 / L = 70 mm, Schaltabstand 7 mm nicht bündig einbaubar, Schließer, DC, PNP, M12 Steckverbindung, IP 67, IP 69K, 3-Leiter, Umgebungstemperatur -40...85 °C, Schaltfrequenz 300 Hz