EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 RF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-5 Surge / 0.5 kV line to line, Ri: 2 Ohm; EN 61000-4-6 RF conducted / 10 V; EN 55011 / Class B
MTTF
2388 years
Detection range
Working distance
0...3,25 mm
Increased switching distance
Displays / controls
Indication
Switching state / 1 x LED, yellow
Electrical connection - Plug
Cable
0.8 m, PUR; 3 x 0.34 mm²
Plug connection
1 x M12; coding: A; contacts: 4
Electrical data
Operating voltage
10...36 DC V
Electricity consumption
10; (24 V) mA
Protection class
III
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...70 °C
Degree of protection
IP 68; ("Coolant")
Field of application
Special feature
Increased switching distance
Application
Industrial applications / factory automation; use in machine tools, coolant and lubricant systems
Mechanical data
Mounting type
Flush-mountable
Thread designation
M12 x 1
Materials
Housing: brass, white bronze-coated; active surface: LCP; mounting nuts: brass coated
Outputs
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
100 mA
Switching frequency DC
700 Hz
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP
Output function
Normally open contact
Switching distance
4 mm
Housing
Threaded design
Dimensions
M12 x 1 / L = 39 mm
Induktiver Sensor, M12 x 1 / L = 39 mm, Schaltabstand 4 mm bündig einbaubar, Schließer, DC, PNP, 0,8 m PUR-Kabel, M12 Steckverbindung, IP 68, ('Coolant'), 3-Leiter, Umgebungstemperatur -25...70 °C, Schaltfrequenz 700 Hz