EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 RF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 RF conducted / 10 V; EN 55011 / Class B
MTTF
1696 years
UL approval
Ta / -25...70 °C; Enclosure type / Type 1; Power supply / Limited Voltage/Current; File Number UL / E174191
AS-i parameters
AS-i version
2.1
AS-i I/O configuration
0 hex
AS-i ID code
A.F hex
AS-i certificate
57101
Data bit assignment
Name / Switch signal / not used / not used / not used; State = 0 / Target outside active range / - / - / -; State = 1 / Target within active range / Default value / Default value / Default value
Extended addressing mode
Detection range
Real switching distance Sr
7 ± 10 % mm
Working distance
0...5,7 mm
Displays / controls
Indication
Switching state / 4 x 90° LED, yellow; function / 1 x LED, red
Electrical connection - Plug
Plug connection
1 x M12; Coding: A; Contacts: 4, gold-plated
Electrical data
Operating voltage
26,5...31,6 DC V
Electricity consumption
< 30 mA
Protection class
III
Max. standby delay time
1000 ms
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...70 °C
Degree of protection
IP 68; ("Coolant")
Field of application
Special feature
Gold-plated contacts
Application
Industrial applications / factory automation; use in machine tools, coolant and lubricant systems
Mechanical data
Mounting type
not flush-mountable
Thread designation
M12 x 1
Materials
1.4404 (stainless steel / 316L); active surface: LCP clear
Outputs
Switching frequency DC
100 Hz
Product features
Electrical version
AS-i
Switching distance
7 mm
Housing
Threaded design
Dimensions
M12 x 1 / L = 60 mm
Induktiver Sensor, M12 x 1 / L = 60 mm, Schaltabstand 7 mm nicht bündig einbaubar, DC, AS-i, M12 Steckverbindung, IP 68, ('Coolant'), 2-Leiter, Umgebungstemperatur -25...70 °C, Schaltfrequenz 100 Hz