EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 RF radiated / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 RF conducted / 10 V; EN 55011 / Class B
MTTF
2110 years
UL approval
Ta / 0...40 °C; Enclosure type / Type 1; File Number UL / E174191
Detection range
Real switching distance Sr
7 ± 10 % mm
Working distance
0...5,7 mm
Increased switching distance
Displays / controls
Indication
Switching state / 4 x 90° LED, yellow
Electrical connection - Plug
Plug connection
1 x M12; Coding: A; Contacts: 4, gold-plated
Electrical data
Operating voltage
10...30 DC V
Protection class
II
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...70 °C
Degree of protection
IP 68; ("Coolant")
Field of application
Special feature
Gold-plated contacts; Increased switching gap
Application
Industrial applications / factory automation; use in machine tools, coolant and lubricant systems
Mechanical data
Mounting type
not flush-mountable
Thread designation
M12 x 1
Materials
Housing: brass, white bronze-coated; active surface: LCP
Outputs
Max. voltage drop switching output DC
2,5 V
Minimum load current
2 mA
Max. residual current
0,5 mA
Continuous current rating of switching output DC
100 mA
Switching frequency DC
700 Hz
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP/NPN
Output function
Normally open contact
Switching distance
7 mm
Housing
Threaded design
Dimensions
M12 x 1 / L = 50 mm
Induktiver Sensor, M12 x 1 / L = 50 mm, Schaltabstand 7 mm nicht bündig einbaubar, Schließer, DC, PNP/NPN, M12 Steckverbindung, IP 68, ('Coolant'), 2-Leiter, Umgebungstemperatur -25...70 °C, Schaltfrequenz 700 Hz