EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 radiated HF / 10 V/m; EN 61000-4-4 burst / 2 kV; EN 61000-4-6 conducted HF / 3 V; EN 55011 / Class B
UL approval
Ta / < 40 °C; Enclosure type / Type 1; Power supply / Class 2; File number UL / E174191
Detection range
Real switching distance Sr
1,5 ± 10 % mm
Working distance
0...1,2 mm
Displays / controls
Indication
Switching state / 1 x LED, yellow
Electrical connection
Cable
2 m, PVC; 3 x 0.14 mm²
Electrical data
Operating voltage
10...30 DC; ("supply class 2" according to cULus) V
Electricity consumption
10; (24 V) mA
Protection class
III
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...70 °C
Degree of protection
IP 67
Field of application
Application
Industrial applications / factory automation; Suitable for use in confined installation conditions
Mechanical data
Mounting type
Flush-mountable
Thread designation
M8 x 1
Materials
Housing: Nickel-plated brass; active surface: LCP
Outputs
Max. voltage drop switching output DC
1,5 V
Continuous current rating of switching output DC
100 mA
Switching frequency DC
4000 Hz
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP
Output function
Breaker contact
Switching distance
1,5 mm
Housing
Threaded design
Dimensions
M8 x 1 / L = 20 mm
Induktiver Sensor, M8 x 1 / L = 20 mm, Schaltabstand 1,5 mm bündig einbaubar, Öffner, DC, PNP, 2 m PVC-Kabel, IP 67, 3-Leiter, Umgebungstemperatur -25...70 °C, Schaltfrequenz 4000 Hz