EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 radiated HF / 3 V/m; EN 61000-4-4 burst / 2 kV; EN 61000-4-6 conducted HF / 3 V; EN 55011 emission / Class B
MTTF
611 years
Detection range
Real switching distance Sr
20 ± 10 % mm
Working distance
0...16,2 mm
Displays / controls
Indication
Switching state / 1 x LED, yellow
Electrical connection
Required fuse rating
Miniature fuse according to IEC60127-2 Sheet 1; ≤ 2 A; fast
Cable
6 m, Silicone; 2 x 0.75 mm²
Electrical data
Operating voltage
20...250 AC/DC V
Protection class
II
Reverse polarity protected
Environmental conditions
Ambient temperature
-25...100 °C
Degree of protection
IP 67
Field of application
Application
Industrial applications / factory automation
Mechanical data
Mounting type
not flush-mountable
Materials
Housing: PBT; plug: TPE
Outputs
Max. voltage drop switching output DC
6 V
Max. voltage drop switching output AC
6,5 V
Minimum load current
5 mA
Max. residual current
2,5 (250 V AC) / 1,3 (110 V AC) / 0,8 (24 V DC) mA
Continuous current rating of switching output AC
100; (350 (...50 °C)) mA
Continuous current rating of switching output DC
100 mA
Short-term current rating of switching output
2200; (20 ms / 0,5 Hz) mA
Switching frequency AC
25 Hz
Switching frequency DC
50 Hz
Short-circuit-proof
Overload resistant
Product features
Output function
Breaker contact
Switching distance
20 mm
Housing
Cylindrical
Dimensions
Ø 34 / L = 82 mm
Remarks
Remarks
Recommendation: After a short circuit, check the device for safe operation.
Induktiver Sensor, Ø 34 / L = 82 mm, Schaltabstand 20 mm nicht bündig einbaubar, Öffner, AC/DC, 6 m Silikon-Kabel, IP 67, 2-Leiter, Umgebungstemperatur -25...100 °C, Schaltfrequenz 25 Hz AC / 50 Hz DC