| Accessories |
| Scope of delivery | O-rings: 1 x (26 x 3 mm), EPDM, FDA-compliant, E30438; O-rings: 1 x (26 x 3 mm), FKM, FDA-compliant, E30437 |
| Approvals / tests |
| Printer directive | A possible classification according to the Pressure Equipment Directive is application-specific and must be carried out by the user / operator. |
| Safety instructions | The compatibility between medium and product material must be checked in all applications. |
| Field of application |
| Model | with leakage hole |
| Compressive strength | 100 bar / 10 MPa |
| Mechanical data |
| Materials in contact with the medium | 1.4435 (Stainless steel / 316L) Surface finish: Ra < 0.4 µm / Rz = 4 µm |
| Sensor connection | G 1 sealing cone - 27 mm |
| Process connection | Clamp DN25...DN40 (1...1.5") DIN 32676 (ISO 2852) |
| Suitable for process connection standard | DIN 32676 Series A (DIN) / Clamp DN32, DN40; DIN 32676 Series B (ISO) / Clamp DN33,7; DIN 32676 Series C (ASME BPE) / Clamp 1,5"; ISO 2852 / Clamp DN33,7, DN38 |
| Sealing | Sealing ring |
| Hygiene class according to DIN 11866 | H4 |
Prozessadapter Tri-Clamp, Sensorikanschluss G 1 Dichtkonus, Prozessanschluss Clamp DN25...DN40 (1...1,5'), Druckfestigkeit 100 bar, Zulassung 3-A, EC1935/2004, FDA