| Approvals / tests |
| EMC | EN 61000-6-1; EN 61000-6-2; EN 61000-6-3; EN 61000-6-4; EN 61000-3-2 / Class A |
| Vibration resistance | IEC 60068-2-6 / ±1.6 mm 2...17.8 Hz / 2 g 17.8...500 Hz |
| Shock resistance | IEC 60068-2-27 / 30 g 6 ms / 20 g 11 ms |
| MTTF | 111 years |
| Power factor correction PFC | complies |
| Displays / controls |
| Indication | DC ok / 1 x LED |
| Electrical data |
| AC frequency | 47...64 Hz |
| Nominal voltage AC | < 400 V |
| Input voltage range AC | 380...480; (-15 % / +20 %) V |
| DC output voltage | 24...28 V |
| Protection class | I; (IEC 61140) |
| Over voltage protection | ja; (< 32 DC) |
| Output voltage | adjustable; output voltage according to SELV, PELV V |
| Max. output current at min. output voltage | 10 A |
| Max. output current at max. output voltage | 8,6 A |
| Max. output current short-term at min. output voltage | 12 A |
| Max. output current short-term at max. output voltage | 10,3 A |
| Output power (continuous) | 240 W |
| Output power (temporary) | 288 W |
| Note on output power (temporary) | ≤ 45 °C permanently allowed; > 45 °C < 1 minute every 10 minutes W |
| Power factor (rated voltage 400 V AC / 50 Hz) | 0,53 |
| Note on power factor (rated voltage 400 V AC / 50 Hz) | at symmetrical phase voltage |
| Power factor (rated voltage 480 V AC / 50 Hz) | 0,52 |
| Note on power factor (rated voltage 480 V AC / 50 Hz) | at symmetrical phase voltage |
| Power reserve | 20 % |
| Number of output circuits | 1 |
| Max. ripple | 50 mV |
| Inrush current (rated voltage 400 V AC / 60 Hz) | 4 A |
| Inrush current (rated voltage 480 V AC / 50 Hz) | 4 A |
| Efficiency (rated voltage 400 V AC / 60 Hz) | 92,8 % |
| Efficiency (rated voltage 480 V AC / 50 Hz) | 92,9 % |
| External input fuse | ≥ B-6 A / ≥ C-3 A |
| Derating | 6 (60...70 °C) W/K |
| Power failure bridging time (nominal voltage 400 V AC / 60 Hz) | 34 ms |
| Power outage bridging time (nominal voltage 480 V AC / 50 Hz) | 54 ms |
| Input current (rated voltage 400 V AC / 60 Hz) | 0,7 A |
| Input current (rated voltage 480 V AC / 50 Hz) | 0,6 A |
| Power loss (rated voltage 400 V AC / 60 Hz) | 18,6 W |
| Power loss (rated voltage 480 V AC / 50 Hz) | 18,3 W |
| Reverse voltage withstand | 35 V |
| Inrush current limitation | |
| Environmental conditions |
| Ambient temperature | -25...70 °C |
| Note on ambient temperature | Allow for free spaces for convection (see operating instructions) |
| Storage temperature | -40...85 °C |
| Maximum permissible relative humidity | 95; (IEC 60068-2-30) % |
| Degree of protection | IP 20; (EN 60529) |
| Pollution degree | 2; (IEC 62103: conductive pollution not permitted) |
| Field of application |
| Model | DIN rail housing |
| Mechanical data |
| Housing | rectangular |
| Mounting method | DIN rail mounting; (TH35 (EN 60715)) |
| Dimensions | 124 x 62 x 122,5 mm |
| Materials | housing: sheet steel |
| Outputs |
| Overload behaviour | constant output current |
| DC-OK signal configuration | Relay output |
| Load capacity DC-OK signal | 60 V DC (0,3 A) / 30 V DC (1 A) / 30 V AC (0,5 A) |
| Short-circuit-proof | |
| Overload resistant | |
| Remarks |
| Remarks | Series connection of outputs is only valid for identical devices up to max. 150 V DC total voltage |
Schaltnetzteil 24 V DC, 10 A, Eingangsspannung AC 380...480 V, 124 x 62 x 122,5 mm, Anschlussklemmen, Zulassung, cRUus, cULus, UKCA