| Accessories |
| Scope of delivery | Fastening nuts: 2 |
| Accuracy / Deviations |
| Correction factor | steel: 1 / stainless steel: 0.8 / brass: 0.5 / aluminium: 0.5 / copper: 0.4 |
| Hysteresis | 10 % of Sr |
| Approvals / tests |
| Approval | IECEx BVS 17.0094X |
| ATEX equipment marking | II 3D Ex tc IIIC T80°C Dc X |
| EMC | EN 60947-5-2 |
| MTTF | 435 years |
| Detection range |
| Real switching distance Sr | 10 ± 10 % mm |
| Working distance | 0...8,1 mm |
| Adjustable switching distance | |
| Displays / controls |
| Indication | Switching state / 2 x LED, yellow |
| Electrical connection |
| Required fuse rating | Miniature fuse according to IEC60127-2 Sheet 1; ≤ 2 A; fast; Place the fuse outside the explosive hazard area. |
| Cable | 2 m, PUR; 2 x 0.5 mm² |
| Electrical data |
| Nominal voltage AC | 20...250 V |
| Nominal voltage DC | 20...250 V |
| Rated frequency AC | 45...65 Hz |
| Protection class | II |
| Reverse polarity protected | |
| Environmental conditions |
| Ambient temperature | -20...60 °C |
| Storage temperature | -25...60 °C |
| Degree of protection | IP 65; IP 67 |
| Field of application |
| Application | Simple evaluation of rotational and linear movements for undershoot of setpoint; blocking |
| Measurement / adjustment range |
| Adjustment range | 5...3600 Imp/min |
| Measurement principle | Inductive |
| Mechanical data |
| Mounting type | Flush-mountable |
| Thread designation | M30 x 1.5 |
| Materials | Housing: special-coated brass; PA; TPE-U |
| Outputs |
| Total number of outputs | 1 |
| Max. voltage drop switching output DC | 8,5 V |
| Minimum load current | 6 mA |
| Max. residual current | 1,5 mA |
| Continuous current rating of switching output AC | 200 mA |
| Continuous current rating of switching output DC | 100 mA |
| Short-term current rating of switching output | 2200; (20 ms / 0,5 Hz) mA |
| Short-circuit-proof | |
| Overload resistant | |
| Product features |
| Output function | Normally open contact |
| Switching distance | 10 mm |
| Housing | Threaded design |
| Dimensions | M30 x 1,5 / L = 80 mm |
| Remarks |
| Remarks | Recommendation: After a short circuit, check the device for safe operation! |
| Response times |
| Start-up bridging | 12 s |
| Max. damping frequency | 4800 imp/min |
| Software / Programming |
| Switching point adjustment | Multi-turn potentiometer |
Drehzahlwächter, M30 x 1,5 / L = 80 mm, Schließer, 10 mm, bündig einbaubar, Anschlussleitung