| Accuracy / Deviations |
| Hysteresis | 5 % |
| Notes on accuracy / deviation | Allowed frequency difference between inputs: ≤ 10 % (f > 100 Hz) / ≤ 20 % (f < 100 Hz) |
| Displays / controls |
| Indication | Voltage / 1x LED, green; Release / 1x LED, yellow; Configuration / 1x LED, blue; Error / 1x LED, red; Switching state / 2x LED, green; Input signal / 2x LED, yellow |
| Electrical connection |
| Screw terminals | 0.5...2.5 mm²; AWG 30...12 |
| Electrical data |
| Operating voltage | 19.2...28.8 DC; (including 5 % ripple) V |
| Nominal voltage DC | 24 V |
| Electricity consumption | < 125 mA |
| Protection class | II |
| Max. standby delay time | 3000 ms |
| Auxiliary power for sensors DC | 24; (≤ 70 mA, voltage drop to operating voltage ≤ 2 V) V |
| Environmental conditions |
| Ambient temperature | -40...55 °C |
| Note on ambient temperature | Allow for free spaces for convection (see operating instructions) |
| Storage temperature | -40...70 °C |
| Maximum permissible relative humidity | 95 % |
| Maximum height above sea level | 2000 m |
| Degree of protection | IP 20 |
| Field of application |
| Model | DIN rail housing |
| Application | Secure evaluation of rotational and linear movements for setpoint exceedance |
| Inputs |
| Input data | S34, S43: "1": 6 mA / 24 V DC |
| Input circuitry for digital inputs | PNP |
| Current through return contacts | < 100 mA |
| Inputs / Outputs |
| Number of inputs and outputs | Number of digital outputs: 2; Number of relay outputs: 2 |
| Measurement / adjustment range |
| Adjustable range Hz | 0,5...990 Hz |
| Adjustment range | 10...49500 Imp/min |
| Frequency range | < 2000; (pulse duration: 100 µs: > 500 Hz ; 150 µs: ≤ 500 Hz) Hz |
| Mechanical data |
| Mounting method | DIN rail mounting; (TH35 (EN 60715)) |
| Materials | Housing: PA |
| Outputs |
| Number of digital outputs | 2 |
| Number of relay outputs | 2 |
| Contact rating | 6 A, 250 V AC / 24 V DC; (≥ 6 mA ; resistive load) |
| Short-circuit protection type | The contacts must be protected by external fuses with a rated current < 3.6 A |
| Current rating per output | 20; (24 V DC, voltage drop to supply voltage ≤ 2 V, not fail-safe) mA |
| Short-circuit-proof | |
| Product features |
| Housing | rectangular |
| Dimensions | 108 x 22,5 x 114,5 mm |
| Electrical version | Relay; (contacts are potential-free) |
| Output function | 1 x fault output "Fault"; 1 x diagnostic output "Overspeed" |
| Remarks |
| Remarks | Safety ratings for 1000 relay operations / year |
| Response times |
| Response time to safety requirement | f sel ≥ 100 Hz: / t = 10.7 + 400 x (f sel ÷ f in); f sel < 100 Hz: / t = 14 + (4500 ÷ f in) ms |
| Risk time (fault response time) | 5,5 ms |
| Legend | t : / response time; f sel : / set frequency (setpoint); f in : / applied frequency (actual value) |
| Safety ratings |
| Complies with requirements | ISO 13849-1 Category 4, PL e; IEC 61508 SIL 3 |
| Service life TM (Mission Time) | ≤175200 h |
| Service life TM (additional information) | 20 years |
| PFH | DC13 (2 A), 24 V DC / 7,69E-09; AC15 (1 A), 230 V AC / 8,25E-09; AC15 (3 A), 230 V AC / 9,15E-09 1/h |
| Hardware fault tolerance HFT | 1; (Type B) |